CoChat

kT‐points: Short three‐dimensional tailored RF pulses for flip‐angle homogenization over an extended volume

Open access
Cloos, M. A., Boulant, N., Luong, M., Ferrand, G., Giacomini, E., Le Bihan, D., Amadon, A. · 2012 · Magnetic Resonance in Medicine
Cited by 225

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

With Transmit SENSE, we demonstrate the feasibility of uniformly exciting a volume such as the human brain at 7T through the use of an original minimalist transmit k‐space coverage, referred to as “kT‐points.” Radio‐frequency energy is deposited only at a limited number of k‐space locations in the vicinity of the center to counteract transmit sensitivity inhomogeneities. The resulting nonselective pulses are short and need little energy compared to adiabatic or other B‐robust pulses available in the literature, making them good candidates for short‐repetition time 3D sequences at high field. Experimental verification was performed on three human volunteers at 7T by means of an 8‐channel transmit array system. On average, whereas the standard circularly polarized excitation resulted in a 33%‐flip angle spread (standard deviation over mean) throughout the brain, and a static radio‐frequency shim showed flip angle variations of 17% and up, application of kT‐point‐based excitations demonstrated excellent flip angle uniformity (8%) for a small target flip angle and with sub‐millisecond durations. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22978

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Cloos, M. A., Boulant, N., Luong, M., Ferrand, G., Giacomini, E., Le Bihan, D., & Amadon, A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2011-05-16
Volume
67
Issue
1
Pages
72-80
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2067489705
Cited by
225
References
3
FWCI
7.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.