Rapid quantification of myocardial lipid content in humans using single breath‐hold 1H MRS at 3 Tesla
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A rapid, proton magnetic resonance spectroscopy method to evaluate human myocardial lipid levels in a single breath‐hold at 3 T using a commercial whole‐body system is presented. During a 10 s breath‐hold, water unsuppressed and suppressed spectra were acquired by two phased array coils using a short‐echo time spectroscopic stimulated echo (STEAM) sequence electrocardiogram‐triggered to mid‐diastole. Lipid‐to‐water ratios were obtained in the septum of 15 healthy volunteers, (0.46 ± 0.19)%. These results agreed well with ratios obtained from averaged spectra acquired in seven multiple breath‐holds, (0.45 ± 0.20)%, providing increased signal‐to‐noise ratio but requiring longer acquisition times. Excellent correlation was found between the two methods (r = 0.94, P < 0.05). Reproducibility of 1 H MRS for measuring myocardial lipid levels in a short breath‐hold was acceptable in five repeated measurements within the same subject (coefficient of variation = 19%). Thus, single breath‐hold proton spectroscopy allows reliable and quick quantification of myocardial lipids at 3 T. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intramyocardial lipid accumulation in the failing human heart resembles the lipotoxic rat heart
Sharma, S., Adrogue, J. V., Golfman, L., Uray, I., Lemm, J., Youker, K., Noon, G. P., Frazier, O. H., & Taegtmeyer, H. (2004) · The FASEB Journal · doi:10.1096/fj.04-2263com · Cited by 790
Rijzewijk, L. J., van der Meer, R. W., Smit, J. W. A., Diamant, M., Bax, J. J., Hammer, S., Romijn, J. A., de Roos, A., & Lamb, H. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.062 · Cited by 559
Cited by
Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease
Banerjee, R., Pavlides, M., Tunnicliffe, E. M., Piechnik, S. K., Sarania, N., Philips, R., Collier, J. D., Booth, J. C., Schneider, J. E., Wang, L. M., et al. (2014) · Journal of Hepatology · doi:10.1016/j.jhep.2013.09.002 · Cited by 498
Self-citationAssessing Cardiac Metabolism: A Scientific Statement From the American Heart Association
Taegtmeyer, H., Young, M. E., Lopaschuk, G. D., Abel, E. D., Brunengraber, H., Darley-Usmar, V., Des Rosiers, C., Gerszten, R., Glatz, J. F., Griffin, J. L., et al. (2016) · Circulation Research · doi:10.1161/res.0000000000000097 · Cited by 286
Self-citationRelationship Between Left Ventricular Structural and Metabolic Remodeling in Type 2 Diabetes
Levelt, E., Mahmod, M., Piechnik, S. K., Ariga, R., Francis, J. M., Rodgers, C. T., Clarke, W. T., Sabharwal, N., Schneider, J. E., Karamitsos, T. D., et al. (2016) · Diabetes · doi:10.2337/db15-0627 · Cited by 254
Self-citationThompson, R. B., Chow, K., Khan, A., Chan, A., Shanks, M., Paterson, I., & Oudit, G. Y. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.000482 · Cited by 194
“The healthy subject lipid content is similar to a previous study.(17) Pathology studies have shown relatively high myocardial concentrations of the glycolipid, ceramide trihexoside (CTH) of 11.”
MethodResultHolloway, C. J., Ntusi, N., Suttie, J., Mahmod, M., Wainwright, E., Clutton, G., Hancock, G., Beak, P., Tajar, A., Piechnik, S. K., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.001719 · Cited by 185
Self-citation
Metadata
- Authors
- Rial, B., Robson, M. D., Neubauer, S., & Schneider, J. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-06-30
- Volume
- 66
- Issue
- 3
- Pages
- 619-624
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2170934133
- Cited by
- 70
- References
- 2
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.