Informed RESTORE: A method for robust estimation of diffusion tensor from low redundancy datasets in the presence of physiological noise artifacts
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Physiological noise artifacts, especially those originating from cardiac pulsation and subject motion, are common in clinical Diffusion tensor‐MRI acquisitions. Previous works show that signal perturbations produced by artifacts can be severe and neglecting to account for their contribution can result in erroneous diffusion tensor values. The Robust Estimation of Tensors by Outlier Rejection (RESTORE) method has been shown to be an effective strategy for improving tensor estimation on a voxel‐by‐voxel basis in the presence of artifactual data points in diffusion‐weighted images. In this article, we address potential instabilities that may arise when using RESTORE and propose practical constraints to improve its usability. Moreover, we introduce a method, called informed RESTORE designed to remove physiological noise artifacts in datasets acquired with low redundancy (less than 30–40 diffusion‐weighted image volumes)—a condition in which the original RESTORE algorithm may converge to an incorrect solution. This new method is based on the notion that physiological noise is more likely to result in signal dropouts than signal increases. Results from both Monte Carlo simulation and clinical diffusion data indicate that informed RESTORE performs very well in removing physiological noise artifacts for low redundancy diffusion‐weighted image datasets. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-citationHigh angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 1×
“Finally, although we applied the RESTORE and iRESTORE algorithms to diffusion tensor imaging, we believe both methods are also useful for other modalities of diffusion data analysis such as the HARDI type of analysis (34).”
MethodDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
“In addition, there is ongoing research on methods to robustly fit the tensor model, in the face of noisy data (Chang et al., 2005, 2012).”
MethodAndersson, J. L. R., Graham, M. S., Zsoldos, E., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.058 · Cited by 763
Studying neuroanatomy using MRI
Lerch, J. P., van der Kouwe, A. J. W., Raznahan, A., Paus, T., Johansen-Berg, H., Miller, K. L., Smith, S. M., Fischl, B., & Sotiropoulos, S. N. (2017) · Nature Neuroscience · doi:10.1038/nn.4501 · Cited by 310
Structural network alterations and neurological dysfunction in cerebral amyloid angiopathy
Reijmer, Y. D., Fotiadis, P., Martinez-Ramirez, S., Salat, D. H., Schultz, A., Shoamanesh, A., Ayres, A. M., Vashkevich, A., Rosas, D., Schwab, K., et al. (2015) · Brain · doi:10.1093/brain/awu316 · Cited by 181
Hutchinson, E. B., Avram, A. V., Irfanoglu, M. O., Koay, C. G., Barnett, A. S., Komlosh, M. E., Özarslan, E., Schwerin, S. C., Juliano, S. L., & Pierpaoli, C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26575 · Cited by 73
“The signal-transformed DWI dataset was obtained according to methods described previously (25,26) in which the noise floor is estimated, after which a b-value– dependent subtraction from each DWI is calculated and applied such that volumes with high signal-to-noise ratio (SNR) are mostly unchanged but those with low S…”
Self-citationGPU acceleration of nonlinear diffusion tensor estimation using CUDA and MPI
Chang, L.-C., El-Araby, E., Dang, V. Q., & Dao, L. H. (2014) · Neurocomputing · doi:10.1016/j.neucom.2013.12.035 · Cited by 15
Self-citation
Metadata
- Authors
- Chang, L., Walker, L., & Pierpaoli, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-01-27
- Volume
- 68
- Issue
- 5
- Pages
- 1654-1663
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2140001755
- Cited by
- 111
- References
- 4
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.