Hexafluorobenzene in comparison with perfluoro‐15‐crown‐5‐ether for repeated monitoring of oxygenation using 19F MRI in a mouse model
Open accessThe DOI matches its Crossref record.
Abstract
Hexafluorobenzene (HFB) and perfluoro‐15‐crown‐5‐ether (15C5) were compared as fluorine reporter probes of tissue oxygenation using 19 F MRI for dynamic assessment of muscle oxygenation, with special focus on muscle tissue toxicity of the probes, and consecutive alteration of animal behavior. The latter were also compared in terms of sensitivity to changes in oxygenation as well as of signal‐to‐noise ratio for accurate p O 2 measurements. For that purpose, mouse muscles were imaged at 11.7 T, at 2‐ and 36‐h after intramuscular injection of HFB or 15C5. Histological analysis of the muscle tissue revealed a lack of toxicity for 15C5 from 2 up to 36‐h postinjection, whereas HFB induced tissue necrosis, blood clots and thrombosis as soon as 24‐h postinjection. This muscle toxicity led to a limitation in mice mobility 24‐h after injection of HFB as evidenced by behavioral testing (open‐field, grip strength, and catwalk tests), which was not the case after 15C5 intramuscular injection. Finally, p O 2 measurements assessed 2‐h postinjection showed consistent values with both probes, evidencing cross‐validation of the 19 F MRI oximetry technique for acute measurements. However, the measurement at 36‐h was hampered for HFB, which showed significant lower values of muscle p O 2, whereas 15C5 was able to reliably assess muscle p O 2 at 36‐h postinjection. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Advanced Functional Nanomaterials for Theranostics
Huang, H., & Lovell, J. F. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201603524 · Cited by 242
Arntson, K. E., & Pomerantz, W. C. K. (2016) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.5b01447 · Cited by 179
Downregulation of the NLRP3 inflammasome by adiponectin rescues Duchenne muscular dystrophy
Boursereau, R., Abou-Samra, M., Lecompte, S., Noel, L., & Brichard, S. M. (2018) · BMC Biology · doi:10.1186/s12915-018-0501-z · Cited by 72
“Results are presented as the mean of the three values of force recorded on the last day and related to body weight [37].”
BackgroundInvolvement of adiponectin in the pathogenesis of dystrophinopathy
Abou-Samra, M., Lecompte, S., Schakman, O., Noel, L., Many, M. C., Gailly, P., & Brichard, S. M. (2015) · Skeletal Muscle · doi:10.1186/s13395-015-0051-9 · Cited by 55
“The grip test measures strength of forelimb or of combined fore- and hindlimb muscles [15].”
Self-citation
Metadata
- Authors
- Mignion, L., Magat, J., Schakman, O., Marbaix, E., Gallez, B., & Jordan, B. F.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-03-22
- Volume
- 69
- Issue
- 1
- Pages
- 248-254
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2147441242
- Cited by
- 47
- References
- 0
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hexafluorobenzene in comparison with perfluoro‐15‐crown‐5‐ether for repeated monitoring of oxygenation using 19F MRI in a mouse model. https://app.cochat.ai/papers/10.1002/mrm.24245
- The paper
- Mignion, L., Magat, J., Schakman, O., Marbaix, E., Gallez, B., & Jordan, B. F. (2013). Hexafluorobenzene in comparison with perfluoro‐15‐crown‐5‐ether for repeated monitoring of oxygenation using 19F MRI in a mouse model. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.