Characterizing inter‐compartmental water exchange in myelinated tissue using relaxation exchange spectroscopy
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Purpose: To investigate inter‐compartmental water exchange in two model myelinated tissues ex vivo using relaxation exchange spectroscopy. Methods: Building upon a previously developed theoretical framework, a three‐compartment (myelin, intra‐axonal, and extra‐axonal water) model of the inversion‐recovery prepared relaxation exchange spectroscopy signal was applied in excised rat optic nerve and frog sciatic nerve samples to estimate the water residence time constants in myelin (τ myelin). Results: In the rat optic nerve samples, τ myelin = 138 ± 15 ms (mean ± standard deviation) was estimated. In sciatic nerve, which possesses thicker myelin sheaths than optic nerve, a much longer τ myelin = 2046 ± 140 ms was observed. Conclusion: Consistent with previous studies in rat spinal cord, the extrapolation of exchange rates in optic nerve to in vivo conditions indicates that τ myelin < 100 ms. This suggests that there is a significant effect of inter‐compartmental water exchange on the transverse relaxation of water protons in white matter. The much longer τ myelin values in sciatic nerve supports the postulate that the inter‐compartmental water exchange rate is mediated by myelin thickness. Together, these findings point to the potential for MRI methods to probe variations in myelin thickness in white matter. Magn Reson Med 70:1450–1459, 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Reaction Rates by Nuclear Magnetic Resonance
McConnell, H. M. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744152 · Cited by 1,624
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
SANDI: a compartment‐based model for non‐invasive apparent soma and neurite imaging by diffusion MRI
Palombo, M., Ianus, A., Guerreri, M., Nunes, D., Alexander, D. C., Shemesh, N., & Zhang, H. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116835 · Cited by 349
“In fact, the T2 of the intra-and extra-cellular compartments may be different (Dortch et al., 2013; Veraart et al., 2018), and here we are additionally neglecting myelin water assuming the echo time is suf fi ciently long to attenuate most of the myelin water contribution through relaxation.”
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Novikov, D. S., Veraart, J., Jelescu, I. O., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.006 · Cited by 237
“We emphasize that the fractions f and 1 f are the relative signal fractions, and not the absolute volume fractions, due to generally different T2 values for the intra- and extra-neurite compartments (Dortch et al., 2013), and due to neglecting myelin water.”
Background
Metadata
- Authors
- Dortch, R. D., Harkins, K. D., Juttukonda, M. R., Gore, J. C., & Does, M. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-12-11
- Volume
- 70
- Issue
- 5
- Pages
- 1450-1459
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1919179105
- Cited by
- 66
- References
- 7
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterizing inter‐compartmental water exchange in myelinated tissue using relaxation exchange spectroscopy. https://app.cochat.ai/papers/10.1002/mrm.24571
- The paper
- Dortch, R. D., Harkins, K. D., Juttukonda, M. R., Gore, J. C., & Does, M. D. (2013). Characterizing inter‐compartmental water exchange in myelinated tissue using relaxation exchange spectroscopy. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.