The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A dedicated neonatal brain imaging system
Open accessAbstract
PURPOSE: The goal of the Developing Human Connectome Project is to acquire MRI in 1000 neonates to create a dynamic map of human brain connectivity during early development. High-quality imaging in this cohort without sedation presents a number of technical and practical challenges. METHODS: We designed a neonatal brain imaging system (NBIS) consisting of a dedicated 32-channel receive array coil and a positioning device that allows placement of the infant's head deep into the coil for maximum signal-to-noise ratio (SNR). Disturbance to the infant was minimized by using an MRI-compatible trolley to prepare and transport the infant and by employing a slow ramp-up and continuation of gradient noise during scanning. Scan repeats were minimized by using a restart capability for diffusion MRI and retrospective motion correction. We measured the 1) SNR gain, 2) number of infants with a completed scan protocol, and 3) number of anatomical images with no motion artifact using NBIS compared with using an adult 32-channel head coil. RESULTS: The NBIS has 2.4 times the SNR of the adult coil and 90% protocol completion rate. CONCLUSION: The NBIS allows advanced neonatal brain imaging techniques to be employed in neonatal brain imaging with high protocol completion rates. Magn Reson Med 78:794-804, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Prospective motion correction in brain imaging: A review
Maclaren, J., Herbst, M., Speck, O., & Zaitsev, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24314 · Cited by 401
Pediatric neuroimaging in early childhood and infancy: challenges and practical guidelines
Raschle, N., Zuk, J., Ortiz‐Mantilla, S., Sliva, D. D., Franceschi, A., Grant, P. E., Benasich, A. A., & Gaab, N. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06457.x · Cited by 264
Transport, monitoring, and successful brain MR imaging in unsedated neonates
Mathur, A. M., Neil, J. J., McKinstry, R. C., & Inder, T. E. (2008) · Pediatric Radiology · doi:10.1007/s00247-007-0705-9 · Cited by 208
Paediatric MRI under sedation: is it necessary? What is the evidence for the alternatives?
Edwards, A. D., & Arthurs, O. J. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2147-7 · Cited by 189
Self-citationTisdall, M. D., Reuter, M., Qureshi, A. Y., Buckner, R. L., Fischl, B. R., & van der Kouwe, A. J. W. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.054 · Cited by 141
MRI evaluation and safety in the developing brain
Tocchio, S., Kline‐Fath, B. M., Kanal, E., Schmithorst, V. J., & Panigrahy, A. (2015) · Seminars in Perinatology · doi:10.1053/j.semperi.2015.01.002 · Cited by 134
Size‐optimized 32‐channel brain arrays for 3 T pediatric imaging
Keil, B. R., Alagappan, V., Mareyam, A., McNab, J. A., Fujimoto, K., Tountcheva, V., Triantafyllou, C., Dilks, D. D., Kanwisher, N., Lin, W., et al. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22961 · Cited by 130
Božek, J., Makropoulos, A., Schuh, A., Fitzgibbon, S. P., Wright, R., Glasser, M. F., Coalson, T. S., O’Muircheartaigh, J., Hutter, J. M., Price, A. N., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.018 · Cited by 121
Self-citationSensitivity Encoding for Aligned Multishot Magnetic Resonance Reconstruction
Cordero‐Grande, L., Teixeira, R. P. A. G., Hughes, E., Hutter, J. M., Price, A. N., & Hajnal, J. V. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2557069 · Cited by 106
Self-citationNeubauer, V., Griesmaier, E., Baumgartner, K., Mallouhi, A., Keller, M., & Kiechl‐Kohlendorfer, U. (2011) · Acta Paediatrica · doi:10.1111/j.1651-2227.2011.02388.x · Cited by 46
Magnetic Resonance Imaging Studies Without Sedation in the Neonatal Intensive Care Unit
Haney, B. M., Reavey, D. A., Atchison, L., Poull, J., Dryer, L., Anderson, B., Sandritter, T. L., & Pallotto, E. K. (2010) · The Journal of Perinatal & Neonatal Nursing · doi:10.1097/jpn.0b013e3181e8d566 · Cited by 40
MR imaging of the neonatal brain at 3 Tesla
Rutherford, M., Malamateniou, C., Zeka, J., & Counsell, S. J. (2004) · European Journal of Paediatric Neurology · doi:10.1016/j.ejpn.2004.08.003 · Cited by 38
Self-citationLarkman (2001) · doi:10.1002/1522-2586(200102)13:2<313::aid-jmri1045>3.0.co;2-w
Cited by
Makropoulos, A., Robinson, E. C., Schuh, A., Wright, R., Fitzgibbon, S., Bozek, J., Counsell, S. J., Steinweg, J., Vecchiato, K., Passerat-Palmbach, J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.054 · Cited by 554
Self-citationLi, J., Chen, J., Tang, Y., Wang, C., Landman, B. A., & Zhou, S. K. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102762 · Cited by 389
Multimodal surface matching with higher-order smoothness constraints
Robinson, E. C., Garcia, K., Glasser, M. F., Chen, Z., Coalson, T. S., Makropoulos, A., Bozek, J., Wright, R., Schuh, A., Webster, M., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.037 · Cited by 324
Self-citationStudying neuroanatomy using MRI
Lerch, J. P., van der Kouwe, A. J. W., Raznahan, A., Paus, T., Johansen-Berg, H., Miller, K. L., Smith, S. M., Fischl, B., & Sotiropoulos, S. N. (2017) · Nature Neuroscience · doi:10.1038/nn.4501 · Cited by 310
Developmental connectomics from infancy through early childhood
Cao, M., Huang, H., & He, Y. (2017) · Trends in Neurosciences · doi:10.1016/j.tins.2017.06.003 · Cited by 284
Metadata
- Authors
- Hughes, E. J., Winchman, T., Padormo, F., Teixeira, R., Wurie, J., Sharma, M., Fox, M., Hutter, J., Cordero-Grande, L., Price, A. N., Allsop, J., Bueno-Conde, J., Tusor, N., Arichi, T., Edwards, A. D., Rutherford, M. A., Counsell, S. J., & Hajnal, J. V.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2016-09-19
- Volume
- 78
- Issue
- 2
- Pages
- 794-804
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W2524545577
- Cited by
- 324
- References
- 16
- FWCI
- 12.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.