Cited by 40Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsNMR spectroscopy and applications

Microstructural correlates of 3D steady-state inhomogeneous magnetization transfer (ihMT) in the human brain white matter assessed by myelin water imaging and diffusion tensor imaging.

Open access
Ercan, Ece, Varma, Gopal, Mädler, Burkhard, Dimitrov, Ivan E., Pinho, Marco C., Xi, Yin, Wagner, Benjamin C., Davenport, Elizabeth M. +4 more·2018·Magnetic Resonance in Medicine

Abstract

Purpose To compare the recently introduced inhomogeneous magnetization transfer (ihMT) technique with more established MRI techniques including myelin water imaging (MWI) and diffusion tensor imaging (DTI), and to evaluate the microstructural attributes correlating with this new contrast method in the human brain white matter. Methods Eight adult healthy volunteers underwent T 1 -weighted, ihMT, MWI, and DTI imaging on a 3T human scanner. The ihMT ratio (ihMTR), myelin water fraction (MWF), fractional anisotropy (FA), radial diffusivity (RD), axial diffusivity (AD), and mean diffusivity (MD) values were calculated from different white matter tracts. The angle ( θ ) between the directions of the principal eigenvector, as measured by DTI, and the main magnetic field was calculated for all voxels from various fiber tracts. The ihMTR was correlated with MWF and DTI metrics. Results A strong correlation was found between ihMTR and MWF (ρ = 0.77, P Conclusion The strong correlation with myelin water imaging and its low coefficient of variation suggest that ihMT has the potential to become a new structural imaging marker of myelin. The substantial orientational dependence of ihMT should be taken into account when evaluating and quantitatively interpreting ihMT results.

Integrity signals

Registry

Crossref · 10.1002/mrm.27211

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ercan, E., Varma, G., Mädler, B., Dimitrov, I. E., Pinho, M. C., Xi, Y., Wagner, B. C., Davenport, E. M., Maldjian, J. A., Alsop, D. C., Lenkinski, R. E., & Vinogradov, E.
Affiliations
  • The University of Texas Southwestern Medical Center (US)
  • Beth Israel Deaconess Medical Center (US)
  • Philips (Germany) (DE)
Corresponding author
Ercan, Ece
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2018-04-29
Volume
80
Issue
6
Pages
2402-2414
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2801987413
Cited by
40
References
2
Citations by year
2026: 1 · 2025: 3 · 2023: 3 · 2022: 12 · 2021: 7 · 2020: 7 · 2019: 6 · 2018: 1
FWCI
3.63
Type
journal article
Language
en
Open access
Locations
  • Magnetic Resonance in Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Leiden Repository (Leiden University) (submittedVersion, cc-by)
  • Leiden Repository (Leiden University) (submittedVersion)
Funders
University of Texas Southwestern Medical Center
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
Keywords
inhomogeneous magnetization transfer, myelin water imaging, diffusion tensor imaging, white matter, myelin, myelin water fraction, fractional anisotropy, radial diffusivity, mean diffusivity, axial diffusivity, fiber orientation, microstructure
MeSH terms
Adult, Brain, Brain Mapping, Computer Simulation, Female, Humans, Image Processing, Computer-Assisted, Magnetics, Male, Myelin Sheath, Pattern Recognition, Automated, Software, Water, Anisotropy, Imaging, Three-Dimensional, Diffusion Magnetic Resonance Imaging, Young Adult, Diffusion Tensor Imaging, Healthy Volunteers, White Matter

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review