Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record.

Anatomical information is needed in ultrasound imaging of muscle to avoid potentially substantial errors in measurement of muscle geometry

Bénard, Menno R., Becher, Jules G., Harlaar, Jaap, Huijing, Peter A., Jaspers, Richard T. · 2009 · Muscle & Nerve

Abstract

This study validates two‐dimensional (2D) ultrasound measurements of muscle geometry of the human medial gastrocnemius (GM) and investigates effects of probe orientation on errors in these measurements. Ultrasound scans of GM muscle belly were made both on human cadavers (n = 4) and on subjects in vivo (n = 5). For half of the cadavers, ultrasound scans obtained according to commonly applied criteria of probe orientation deviated 15° from the true fascicle plane. This resulted in errors of fascicle length and fascicle angle up to 14% and 23%, respectively. Fascicle‐like structures were detectable over a wide range of probe tilt and rotation angles, but they did not always represent true fascicles. Errors of measurement were either linear or quadratic functions of tilt angle. Similar results were found in vivo. Therefore, we conclude that similar errors are likely to occur for in vivo measurements. For all cadavers, at the distal end of GM, the true fascicle plane was shown to be perpendicular to the distal aponeurosis. Using transverse images of GM to detect the curvature of the deep aponeurosis at the distal end of the muscle belly is a simple strategy to help identify the fascicle plane. For subsequent longitudinal imaging, probe alignment within this plane will help minimize measurement errors of fascicle length, fascicle angle, and muscle thickness. Muscle Nerve, 2009

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mus.21287

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Bénard, M. R., Becher, J. G., Harlaar, J., Huijing, P. A., & Jaspers, R. T.
Venue
Muscle & Nerve
Publisher
Wiley
Published
2009-03-16
Volume
39
Issue
5
Pages
652-665
ISSN
  • 0148-639X (ISSN-L)
  • 1097-4598
OpenAlex
W2047962658
Cited by
160
References
0
FWCI
5.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anatomical information is needed in ultrasound imaging of muscle to avoid potentially substantial errors in measurement of muscle geometry. https://app.cochat.ai/papers/10.1002/mus.21287
The paper
Bénard, M. R., Becher, J. G., Harlaar, J., Huijing, P. A., & Jaspers, R. T. (2009). Anatomical information is needed in ultrasound imaging of muscle to avoid potentially substantial errors in measurement of muscle geometry. Muscle & Nerve. https://doi.org/10.1002/mus.21287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.