The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Muscle shear modulus measured with ultrasound shear‐wave elastography across a wide range of contraction intensity
Abstract
Introduction: In this study we examine the repeatability of measuring muscle shear modulus using ultrasound shear‐wave elastography between trials and between days, and the association between shear modulus and contraction intensity over a wide range of intensities. Methods: Shear modulus of the biceps brachii was determined using ultrasound shear‐wave elastography during static elbow flexion (up to 60% of maximal contraction) in healthy young adults. Results: The correspondence of shear modulus was confirmed in phantoms between the manufacturer‐calibrated values and the shear‐wave elastography values. The intraclass correlation coefficient of muscle shear modulus was high: 0.978 between trials and 0.948 between days. Shear modulus increased linearly with elbow flexion torque across contraction intensity, and its slope was associated negatively with muscle strength. Conclusions: Muscle shear modulus measured with ultrasound shear‐wave elastography may be useful for inferring muscle stiffness across a wide range of contraction intensity. In addition, it has high repeatability between trials and between days. Muscle Nerve 50: 103–113, 2014
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Effects of Plyometric and Weight Training on Muscle-Tendon Complex and Jump Performance
KUBO, K., MORIMOTO, M., KOMURO, T., YATA, H., TSUNODA, N., KANEHISA, H., & FUKUNAGA, T. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31813e630a · Cited by 356 · cited 1×
“Muscle mechanical characteristics are important in basic and clinical research for examining the adaptation of skeletal muscles to neuromuscular diseases,(1) muscle injuries,(2) and training.(3) Therefore, the availability of noninvasive and simple operations for quantifying mechanical characteristics of relaxed and c…”
BackgroundSelf-citation
Cited by
Elastography for Muscle Biomechanics: Toward the Estimation of Individual Muscle Force
Hug, F., Tucker, K., Gennisson, J.-L., Tanter, M., & Nordez, A. (2015) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000049 · Cited by 342
Metadata
- Authors
- Yoshitake, Y., Takai, Y., Kanehisa, H., & Shinohara, M.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 2014-05-17
- Volume
- 50
- Issue
- 1
- Pages
- 103-113
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W1493425542
- Cited by
- 196
- References
- 2
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Muscle shear modulus measured with ultrasound shear‐wave elastography across a wide range of contraction intensity. https://app.cochat.ai/papers/10.1002/mus.24104
- The paper
- Yoshitake, Y., Takai, Y., Kanehisa, H., & Shinohara, M. (2014). Muscle shear modulus measured with ultrasound shear‐wave elastography across a wide range of contraction intensity. Muscle & Nerve. https://doi.org/10.1002/mus.24104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.