The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Relationship of manual muscle testing to objective strength measurements
Abstract
This study investigates the relationship between manual muscle test scores (MMT) and quantitative isometric strength measurements (QIS). It also evaluates the implications of that relationship for design of therapeutic trials. Extension and flexion strength at the elbows, hips, and knees of 21 neuromuscular disease patients were tested a total of 26 times utilizing both MMT and QIS testing. Paired data were evaluated with Spearman ranked correlation coefficients, and then QIS was predicted from MMT using Lowess, a consistent form of nonparametric regression. Finally, the implications of the Lowess analysis for designing a therapeutic trial were evaluated. MMT and QIS measurements were significantly correlated in all movements tested. Lowess analysis yielded prediction errors ranging from 16 to 24% of QIS range. Analysis of the sample size needed for a therapeutic trial suggested that a protocol measuring MMT would require more subjects for the same level of statistical significance as a protocol measuring QIS. Since it was not possible to reliably predict QIS values from MMT scores, such conversions are not appropriate for clinical use. This inconsistent relationship between MMT and QIS carries major implications for the design of therapeutic trials. Since therapeutic trials are time consuming, expensive, and most centers do not have large numbers of individuals available, using QIS as an outcome measure is a preferable research design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Jackknife, the Bootstrap and Other Resampling Plans
Efron, B. (1982) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970319 · Cited by 8,120
Cited by
Sit-to-stand test for measuring performance of lower extremity muscles
Bohannon, R. W. (1995) · Perceptual and Motor Skills · doi:10.2466/pms.1995.80.1.163 · Cited by 509
The Manual Muscle Examination for Rotator Cuff Strength: An Electromyographic Investigation
Kelly, B. T., Kadrmas, W. R., & Speer, K. P. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400504 · Cited by 286
Manual muscle testing: does it meet the standards of an adequate screening test?
Bohannon, R. W. (2005) · Clinical Rehabilitation · doi:10.1191/0269215505cr873oa · Cited by 271
Reliability of 3 methods for assessing shoulder strength
Hayes, K., Walton, J. R., Szomor, Z. L., & Murrell, G. A. C. (2002) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2002.119852 · Cited by 262
Metadata
- Authors
- Aitkens, S., Lord, J., Bernauer, E., Fowler, W. M., Lieberman, J. S., & Berck, P.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1989-03
- Volume
- 12
- Issue
- 3
- Pages
- 173-177
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2034889850
- Cited by
- 189
- References
- 1
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.