Pressure measurements during pelvic floor muscle contractions: The effect of different positions of the vaginal measuring device
The DOI matches its Crossref record.
Abstract
The purpose of the present investigation was to assess whether different positions of the vaginal measuring device affect the pressure readings during pelvic floor muscle (PFM) contraction. Twelve women with stress urinary incontinence (SUI) participating in a PFM exercise program, volunteered for the study. The diagnosis of SUI was based on urodynamic investigation and pad test. The mean age of the women was 40.9 years (24–50). The women performed three PFM contractions with a vaginal balloon placed in four different positions: 1) against the vaginal vault and in the posterior fornix, 2) in the proximal upper third of the vagina, 3) with the middle of the balloon 3.5 cm from the introitus vagina and 4) with half of the balloon outside the introitus vagina. The results demonstrated significant differences between recordings from the four vaginal positions: position 1, median pressure 5 cm H 2 O; position 2, 9 cm H 2 O; position 3, 15 cm H 2 O; and position 4, 8 cm H 2 O. It is concluded that the position of the vaginal device affects the results. This may be one important factor which could explain the variability of vaginal pressure recordings during PFM contractions. For most women the highest pressure was recorded in position 3. © 1992 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bo, K., Talseth, T., & Holme, I. (1999) · BMJ · doi:10.1136/bmj.318.7182.487 · Cited by 680
Evaluation of Female Pelvic-Floor Muscle Function and Strength
Bø, K., & Sherburn, M. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.269 · Cited by 613
Self-citationPelvic Floor and Abdominal Muscle Interaction: EMG Activity and Intra-abdominal Pressure
Neumann, P., & Gill, V. (2002) · International Urogynecology Journal · doi:10.1007/s001920200027 · Cited by 383
Bø, K., & Finckenhagen, H. B. (2001) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1034/j.1600-0412.2001.801003.x · Cited by 308
Self-citationInter-rater reliability study of the modified Oxford Grading Scale and the Peritron manometer
Ferreira, C. H. J., Barbosa, P. B., Souza, F. D. O., Antônio, F. I., Franco, M. M., & Bø, K. (2011) · Physiotherapy · doi:10.1016/j.physio.2010.06.007 · Cited by 190
Self-citation
Metadata
- Authors
- Bø, K.
- Venue
- Neurourology and Urodynamics
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 11
- Issue
- 2
- Pages
- 107-113
- ISSN
- 0733-2467 (ISSN-L)
- 1520-6777
- OpenAlex
- W2141349806
- Cited by
- 70
- References
- 0
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pressure measurements during pelvic floor muscle contractions: The effect of different positions of the vaginal measuring device. https://app.cochat.ai/papers/10.1002/nau.1930110205
- The paper
- Bø, K. (1992). Pressure measurements during pelvic floor muscle contractions: The effect of different positions of the vaginal measuring device. Neurourology and Urodynamics. https://doi.org/10.1002/nau.1930110205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.