CoChat
Cited by 240

The DOI matches its Crossref record.

Reliability of pelvic floor muscle strength assessment using different test positions and tools

Frawley, Helena C., Galea, Mary P., Phillips, Bev A., Sherburn, Margaret, Bø, Kari · 2006 · Neurourology and Urodynamics

Abstract

Aims: The aims of this study were to determine the intra‐therapist reliability for digital muscle testing and vaginal manometry on maximum voluntary contraction strength and endurance. In addition, we assessed how reliability varied with different tools and different testing positions. Methods: Subjects included 20 female physiotherapists. The modified Oxford scale was used for the digital muscle testing, and the Peritron™ perineometer was used for the vaginal resting pressure and vaginal squeeze pressure assessments. Strength and endurance testing were performed. The highest of the maximum voluntary contraction scores was used in strength analysis, and a fatigue index value was calculated from the endurance repetitions. Bent‐knee lying, supine, sitting, and standing positions were used. The time interval for between‐session reliability was 2–6 weeks. Results: Kappa values for the between‐session reliability of digital muscle testing were 0.69, 0.69, 0.86, and 0.79 for the four test positions, respectively. Intra‐class correlation coefficient (ICC) values for squeeze pressure readings for the four positions were 0.95, 0.91, 0.96, and 0.92 for maximum voluntary contraction, and 0.05, 0.42, 0.13, and 0.35 for endurance testing. ICC values for resting pressure were 0.74, 0.77, 0.47, and 0.29. Conclusions: Reliability of digital muscle testing was very good in sitting and good in the other three positions. vaginal resting pressure demonstrated very good reliability in all four positions for maximum voluntary contraction, but was unreliable for endurance testing. Vaginal resting pressure was not reliable in upright positions. Both measurement tools are reliable in certain positions, with manometry demonstrating higher reliability coefficients. Neurourol. Urdynam. 25:236–242, 2006. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nau.20201

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 240

Metadata

Authors
Frawley, H. C., Galea, M. P., Phillips, B. A., Sherburn, M., & Bø, K.
Venue
Neurourology and Urodynamics
Publisher
Wiley
Published
2005-11-20
Volume
25
Issue
3
Pages
236-242
ISSN
  • 0733-2467 (ISSN-L)
  • 1520-6777
OpenAlex
W2031174779
Cited by
240
References
0
FWCI
2.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of pelvic floor muscle strength assessment using different test positions and tools. https://app.cochat.ai/papers/10.1002/nau.20201
The paper
Frawley, H. C., Galea, M. P., Phillips, B. A., Sherburn, M., & Bø, K. (2006). Reliability of pelvic floor muscle strength assessment using different test positions and tools. Neurourology and Urodynamics. https://doi.org/10.1002/nau.20201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.