CoChat

Initial experience using a novel nerve stimulator for the management of pudendal neuralgia

Hoang Roberts, Ly, Vollstedt, Annah, Volin, Joshua, McCartney, Teresa, Peters, Kenneth M. · 2021 · Neurourology and Urodynamics
Cited by 14

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Aims: In patients with pudendal neuralgia, prior studies have shown efficacy in chronic stimulation with Interstim® (Medtronic, Inc.). This feasibility study reports on the initial experience of using a wireless system to power an implanted lead at the pudendal nerve, StimWave®, to treat pudendal neuralgia. Methods: Retrospective chart review identified patients with a lead placed at the pudendal nerve for neuralgia and powered wirelessly. Clinical outcomes were assessed at Postoperative visits and phone calls. Administered non‐validated follow‐up questionnaire evaluated the Global Response Assessment, percentage of pain improvement, satisfaction with device, and initial and current settings of the device (h/day of stimulation). Results: Thirteen patients had the StimWave® lead placed at the pudendal nerve, 12 (92%) female and 1 (7.6%) male. Mean age was 50 years (range: 20–58). Failed prior therapies include medical therapy (100%), pelvic floor physical therapy (92%), pudendal nerve blocks (85%), pelvic floor muscle trigger point injections (69%), neuromodulation (30.7%), or surgeries for urogenital pain (23.1%). After the trial period, 10/13 (76.9%) had >50% improvement in pain with 6/13 (46.1%) reporting 100% pain improvement. Nine underwent permanent lead placement. At last postoperative visit (range, 6–83 days), 5/9 patients reported >50% pain improvement. Seven patients reached for phone calls (22–759 days) reported symptoms to be “markedly improved” (n = 2), “moderately improved” (n = 4), or “slightly improved” (n = 1). At follow up, complications included lead migration (n = 2), broken wire (n = 1), or nonfunctioning antenna (n = 2). Conclusion: Complex patients with pudendal neuralgia may benefit from pudendal nerve stimulation via StimWave®.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nau.24735

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 14

  1. 10.1007/s00345-005-0502-8 · doi:10.1007/s00345-005-0502-8
  2. 10.1097/00006123-199708000-00015 · doi:10.1097/00006123-199708000-00015
  3. 10.1002/nau.20823 · DOI · Paper page
  4. Perryman LT, 2018, Spinal cord stimulation costs and complications can be reduced by wireless nanotechnology. A review of traditional equipment expenses compared to wireless stimulation, Am J Anesth Clin Res, 19
  5. 10.1097/01.spv.0000200406.08673.b8 · DOI
  6. 10.1007/s00384-011-1394-2 · DOI
  7. 10.1111/ner.12032 · DOI · Paper page
  8. 10.1111/j.1094-7159.2004.04018.x · doi:10.1111/j.1094-7159.2004.04018.x
  9. 10.1016/S0022-5347(05)67010-3 · DOI · Paper page
  10. 10.1016/j.juro.2011.04.059 · doi:10.1016/j.juro.2011.04.059
  11. 10.1016/j.ejpain.2008.01.014 · DOI · Paper page
  12. 10.1007/s10151-009-0554-7 · DOI
  13. 10.1002/nau.20118 · DOI · Paper page
  14. 10.1007/s00345-014-1304-7 · DOI

Cited by

See all 14

Metadata

Authors
Hoang Roberts, L., Vollstedt, A., Volin, J., McCartney, T., & Peters, K. M.
Venue
Neurourology and Urodynamics
Publisher
Wiley
Published
2021-06-30
Volume
40
Issue
6
Pages
1670-1677
ISSN
  • 0733-2467
  • 1520-6777
Cited by
14
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.