Cited by 14Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsOptical Imaging and Spectroscopy Techniques

A multi-compartmental SE-BOLD interpretation for stimulus-related signal changes in diffusion-weighted functional MRI

Open access
Kershaw, Jeff, Tomiyasu, Moyoko, Kashikura, Kenichi, Hirano, Yoshiyuki, Nonaka, Hiroi, Hirano, Masaya, Ikehira, Hiroo, Kanno, Iwao +1 more·2009·NMR in Biomedicine

Abstract

A new interpretation is proposed for stimulus-induced signal changes in diffusion-weighted functional MRI. T(2)-weighted spin-echo echo-planar images were acquired at different diffusion-weightings while visual stimulation was presented to human volunteers. The amplitudes of the positive stimulus-correlated response and post-stimulus undershoot (PSU) in the functional time-courses were found to follow different trends as a function of b-value. Data were analysed using a three-compartment signal model, with one compartment being purely vascular and the other two dominated by fast- and slow-diffusing molecules in the brain tissue. The diffusion coefficients of the tissue were assumed to be constant throughout the experiments. It is shown that the stimulus-induced signal changes can be decomposed into independent contributions originating from each of the three compartments. After decomposition, the fast-diffusion phase displays a substantial PSU, while the slow-diffusion phase demonstrates a highly reproducible and stimulus-correlated time-course with minimal undershoot. The decomposed responses are interpreted in terms of the spin-echo blood oxygenation level dependent (SE-BOLD) effect, and it is proposed that the signal produced by fast- and slow-diffusing molecules reflect a sensitivity to susceptibility changes in arteriole/venule- and capillary-sized vessels, respectively. This interpretation suggests that diffusion-weighted SE-BOLD imaging may provide subtle information a…

Integrity signals

Registry

Crossref · 10.1002/nbm.1391

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • T2-weighted spin-echo diffusion MRI retains residual vascular effects related to BOLD.

    “T2-weighted spin-echo diffusion MRI retains residual vascular effects related to BOLD (Aso et al., 2009; de Riedmatten, Spencer, Olszowy, et al., 2025; Kershaw et al., 2009; Miller et al., 2007).”

    From 40 Years of diffusion MRI in the brain: From history to emerging frontiers (2026) · cites this paper as Kershaw et al., 2009

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kershaw, J., Tomiyasu, M., Kashikura, K., Hirano, Y., Nonaka, H., Hirano, M., Ikehira, H., Kanno, I., & Obata, T.
Affiliations
  • National Institute of Radiological Sciences (JP)
  • Gunma Prefectural College of Health Sciences (JP)
  • GE HealthCare (Japan) (JP)
Corresponding author
Obata, Takayuki
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2009-05-06
Volume
22
Issue
7
Pages
770-778
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2024997856
Cited by
14
References
1
Citations by year
2026: 1 · 2017: 1 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 2
FWCI
1.50
Type
journal article
Language
en
Open access
Locations
  • NMR in Biomedicine (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
Funders
Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japanese Government.
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
spin-echo echo-planar imaging, diffusion coefficient, vascular compartment, hemodynamic response, neural responses, visual stimulation
MeSH terms
Adult, Female, Humans, Male, Oxygen, Photic Stimulation, Spin Labels, Time Factors, Diffusion Magnetic Resonance Imaging, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review