The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Real‐time MRI at a resolution of 20 ms
Open accessAbstract
The desire to visualize noninvasively physiological processes at high temporal resolution has been a driving force for the development of MRI since its inception in 1973. In this article, we describe a unique method for real‐time MRI that reduces image acquisition times to only 20 ms. Although approaching the ultimate limit of MRI technology, the method yields high image quality in terms of spatial resolution, signal‐to‐noise ratio and the absence of artifacts. As proposed previously, a fast low‐angle shot (FLASH) gradient‐echo MRI technique (which allows for rapid and continuous image acquisitions) is combined with a radial encoding scheme (which offers motion robustness and moderate tolerance to data undersampling) and, most importantly, an iterative image reconstruction by regularized nonlinear inversion (which exploits the advantages of parallel imaging with multiple receiver coils). In this article, the extension of regularization and filtering to the temporal domain exploits consistencies in successive data acquisitions and thereby enhances the degree of radial undersampling in a hitherto unexpected manner by one order of magnitude. The results obtained for turbulent flow, human speech production and human heart function demonstrate considerable potential for real‐time MRI studies of dynamic processes in a wide range of scientific and clinical settings. Copyright © 2010 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
David, F. N., & Tukey, J. W. (1977) · Biometrics · doi:10.2307/2529486 · Cited by 12,708
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Osborn, J. F., & Tukey, J. W. (1978) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344492 · Cited by 1,190
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
Self-citation
Cited by
Feng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667
A review of disintegration mechanisms and measurement techniques
Markl, D., & Zeitler, J. A. (2017) · Pharmaceutical Research · doi:10.1007/s11095-017-2129-z · Cited by 439
Inspiration is the major regulator of human CSF flow.
Dreha-Kulaczewski, S., Joseph, A. A., Merboldt, K.-D., Ludwig, H.-C., Gärtner, J., & Frahm, J. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3246-14.2015 · Cited by 405
“Subsequent developments achieved true real-time imaging with acquisition times as short as 20 ms by exploiting the temporal continuity of a dynamic movement (Uecker et al., 2010).”
BackgroundSelf-citationSteinmetz, M., Stümpfig, T., Seehase, M., Schuster, A., Kowallick, J., Müller, M., Unterberg-Buchwald, C., Kutty, S., Lotz, J., Uecker, M., et al. (2021) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.120.011823 · Cited by 25
Self-citation
Metadata
- Authors
- Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2010-08-27
- Volume
- 23
- Issue
- 8
- Pages
- 986-994
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2112484408
- Cited by
- 434
- References
- 23
- FWCI
- 13.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐time MRI at a resolution of 20 ms. https://app.cochat.ai/papers/10.1002/nbm.1585
- The paper
- Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J. (2010). Real‐time MRI at a resolution of 20 ms. NMR in Biomedicine. https://doi.org/10.1002/nbm.1585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.