High angular resolution diffusion imaging with stimulated echoes: compensation and correction in experiment design and analysis
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Stimulated echo acquisition mode (STEAM) diffusion MRI can be advantageous over pulsed‐gradient spin‐echo (PGSE) for diffusion times that are long compared with T2. It therefore has potential for biomedical diffusion imaging applications at 7T and above where T2 is short. However, gradient pulses other than the diffusion gradients in the STEAM sequence contribute much greater diffusion weighting than in PGSE and lead to a disrupted experimental design. Here, we introduce a simple compensation to the STEAM acquisition that avoids the orientational bias and disrupted experiment design that these gradient pulses can otherwise produce. The compensation is simple to implement by adjusting the gradient vectors in the diffusion pulses of the STEAM sequence, so that the net effective gradient vector including contributions from diffusion and other gradient pulses is as the experiment intends. High angular resolution diffusion imaging (HARDI) data were acquired with and without the proposed compensation. The data were processed to derive standard diffusion tensor imaging (DTI) maps, which highlight the need for the compensation. Ignoring the other gradient pulses, a bias in DTI parameters from STEAM acquisition is found, due both to confounds in the analysis and the experiment design. Retrospectively correcting the analysis with a calculation of the full B matrix can partly correct for these confounds, but an acquisition that is compensated as proposed is needed to remove the effect entirely. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 6×
“Our choice comes from inverting Equation [8]:”
BackgroundMethodInfluentialOrientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Self-citationAn analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“τdd 1⁄4 τ1 þ τ2 þ τm þ 2δc þ 2δd=3þ 2δs; τcc 1⁄4 τm þ 2δc=3þ 2δs; τss 1⁄4 τm þ 2δs=3; τdc 1⁄4 τm þ δc þ 2δs; τds 1⁄4 τm þ δs; τcs 1⁄4 τm þ δs [7]”
Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305
Cited by
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Self-citationIn vivo observation and biophysical interpretation of time-dependent diffusion in human white matter
Fieremans, E., Burcaw, L. M., Lee, H.-H., Lemberskiy, G., Veraart, J., & Novikov, D. S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.018 · Cited by 181
“…derived from the DTI estimation by the unweighted LLS estimator (Veraart et al., 2013) and a corrected full b-matrix which incorporated the effective gradient from the diffusion, imaging gradients, and radiofrequency (RF) pulse magnetization inversions (Lundell et al., 2014; Sigmund et al., 2013).”
BackgroundMethodInfluentialImaging laminar structures in the gray matter with diffusion MRI
Assaf, Y. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.096 · Cited by 108
Effect of inaccurate b-values from imaging gradients on intravoxel incoherent motion
Rashid, I. A., Szczepankiewicz, F., Gunnlaugsson, A., Olsson, L. E., & Brynolfsson, P. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30579 · Cited by 8
“31 It has been consistently found that imaging resolution and pulse sequence design are important factors, and that accounting for these effects in acquisition or postprocessing improves accuracy.”
Metadata
- Authors
- Lundell, H., Alexander, D. C., & Dyrby, T. B.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2014-06-03
- Volume
- 27
- Issue
- 8
- Pages
- 918-925
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2143671152
- Cited by
- 44
- References
- 4
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.