Cited by 84Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMultiple Sclerosis Research Studies

Can T1w/T2w ratio be used as a myelin‐specific measure in subcortical structures? Comparisons between FSE‐based T1w/T2w ratios, GRASE‐based T1w/T2w ratios and multi‐echo GRASE‐based myelin water fractions

Uddin, Md Nasir, Figley, Teresa D., Marrie, Ruth Ann, Figley, Chase R., for the CCOMS Study Group·2018·NMR in Biomedicine

Abstract

Given the growing popularity of T 1 -weighted/T 2 -weighted (T 1 w/T 2 w) ratio measurements, the objective of the current study was to evaluate the concordance between T 1 w/T 2 w ratios obtained using conventional fast spin echo (FSE) versus combined gradient and spin echo (GRASE) sequences for T 2 w image acquisition, and to compare the resulting T 1 w/T 2 w ratios with histologically validated myelin water fraction (MWF) measurements in several subcortical brain structures. In order to compare these measurements across a relatively wide range of myelin concentrations, whole-brain T 1 w magnetization prepared rapid acquisition gradient echo (MPRAGE), T 2 w FSE and three-dimensional multi-echo GRASE data were acquired from 10 participants with multiple sclerosis at 3 T. Then, after high-dimensional, non-linear warping, region of interest (ROI) analyses were performed to compare T 1 w/T 2 w ratios and MWF estimates (across participants and brain regions) in 11 bilateral white matter (WM) and four bilateral subcortical grey matter (SGM) structures extracted from the JHU_MNI_SS 'Eve' atlas. Although the GRASE sequence systematically underestimated T 1 w/T 2 w values compared to the FSE sequence (revealed by Bland-Altman and mountain plots), linear regressions across participants and ROIs revealed consistently high correlations between the two methods (r 2 = 0.62 for all ROIs, r 2 = 0.62 for WM structures and r 2 = 0.73 for SGM structures). However, correlations between either…

Integrity signals

Registry

Crossref · 10.1002/nbm.3868

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other quantitative MRI techniques such as calibrated T1w/T2w ratio mapping, inhomogeneous magnetization transfer (ihMT) imaging, and T2 relaxation-based myelin water imaging (MWI) are likely less affected by fiber orientation.

    “other quantitative MRI techniques such as calibrated T1w/T2w ratio mapping (Ganzetti et al., 2014; Uddin et al., 2018), inhomogeneous magnetization transfer (ihMT) imaging (Manning et al., 2017; Swanson et al., 2017), and T2 relaxation-based myelin water imaging MWI (Prasloski et al., 2012; Lee et al., 2018) are likely less affected by fiber orientation”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Uddin, M. N., Figley, T. D., Marrie, R. A., Figley, C. R., & for the CCOMS Study Group
Affiliations
  • Health Sciences Centre (CA)
  • University of Manitoba (CA)
  • Dalhousie University (CA)
Corresponding author
Figley, Chase R.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2018-01-09
Volume
31
Issue
3
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2783800543
Cited by
84
References
2
Citations by year
2026: 10 · 2025: 5 · 2024: 5 · 2023: 14 · 2022: 16 · 2021: 6 · 2020: 12 · 2019: 12 · 2018: 4
FWCI
5.87
Type
journal article
Language
en
Open access
closed
Locations
  • NMR in Biomedicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
Canadian Institutes of Health Research (THC‐135234)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Multiple Sclerosis Research Studies
Keywords
T1w/T2w ratio, myelin water fraction, subcortical gray matter, white matter, fast spin echo, GRASE, MPRAGE, multiple sclerosis, myelin quantification, MRI sequence comparison, subcortical structures, histopathological confirmation, brain MRI biomarkers, T2-weighted imaging
MeSH terms
Adult, Aged, Aged, 80 and over, Cerebral Cortex, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Myelin Sheath, Spin Labels, Water, Linear Models, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review