Senile plaques do not induce susceptibility effects in T2*‐weighted MR microscopic images
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Senile plaques are the hallmarks of Alzheimer's disease. They typically range from 16 to 150 µm in size with most less than 25 µm. Mechanisms by which they might affect MR contrast and thus be made visible in this imaging modality are still unknown. Plausibility studies suggested that they might have a different magnetic susceptibility than surrounding tissue. A large difference would cause the plaque and a relatively large volume of adjacent tissue to be hypo‐intense in T2*‐weighted MRI scans, thus causing them to appear larger than their actual sizes and perhaps visible even when their size is below the nominal resolution limit of the imaging experiment. To evaluate this hypothesis, formalin‐fixed superior temporal gyrus samples obtained from two Alzheimer's disease and two control subjects were imaged using magnetic resonance microscopy at 11.7 T. Three dimensional T2*‐weighted gradient echo images were recorded with an isotropic resolution of 23.4 µm. The imaging protocol was especially sensitive to susceptibility effects. Samples were then stained for amyloid and/or iron deposits. Hypo‐ and hyper‐intense structures were clearly visible in MR images from all samples. Hyper‐intense structures reflected fixative penetration within the vascular system. Almost all the hypo‐intense structures were blood vessels. Their hypo‐intense profile was probably caused by iron deposits associated with the cell aggregates that they contained. Only one hypo‐intense spot could be matched with a plaque and this was one of the largest plaques in our samples. The remainder of the several hundred plaques were not visible in MR images. In histological slices the senile plaques were often larger than small blood vessels that were visible in the MR images. This suggests that susceptibility effects are not associated with senile plaques and do not provide a mechanism to differentiate them from surrounding tissue. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ball, M. J. (1997) · Neurobiology of Aging · doi:10.1016/s0197-4580(97)00052-3 · Cited by 34
Cited by
PET imaging of amyloid in Alzheimer's disease
Nordberg, A. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(04)00853-1 · Cited by 464
High‐field magnetic resonance imaging of brain iron: birth of a biomarker?
Schenck, J. F., & Zimmerman, E. A. (2004) · NMR in Biomedicine · doi:10.1002/nbm.922 · Cited by 337
Detection of Alzheimer's amyloid in transgenic mice using magnetic resonance microimaging
Wadghiri, Y. Z., Sigurdsson, E. M., Sadowski, M., Elliott, J. I., Li, Y., Scholtzova, H., Tang, C. Y., Aguinaldo, G., Pappolla, M., Duff, K., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10529 · Cited by 280
Jack, C. R., Garwood, M., Wengenack, T. M., Borowski, B., Curran, G. L., Lin, J., Adriany, G., Gröhn, O. H. J., Grimm, R., & Poduslo, J. F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20266 · Cited by 199
Gong, N.-J., Dibb, R., Bulk, M., van der Weerd, L., & Liu, C. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.019 · Cited by 162
Metadata
- Authors
- Dhenain, M., Privat, N., Duyckaerts, C., & Jacobs, R. E.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2002-02-28
- Volume
- 15
- Issue
- 3
- Pages
- 197-203
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2006805877
- Cited by
- 72
- References
- 1
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.