BOLD MRI mapping of transient hyperemia in skeletal muscle after single contractions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Transient increases in signal intensity (ΔSI, peak 2.6 ± 0.6 %, mean ± SE, n = 14) were observed in axial, gradient‐echo, echo‐planar magnetic resonance images acquired at 1.5 T from human anterior tibialis muscle following single, 1 s duration, isometric ankle dorsiflexion contractions. The magnitude of the MRI‐measured ΔSI was not significantly different using TR of 2000 vs 500 ms, or using spin‐echo vs gradient‐echo echo‐planar pulse sequences. However, ΔSI measured by gradient‐echo sequences was significantly greater at 3 vs 1.5 T (3.8 ± 0.8 vs 1.6 ± 0.2 %, n = 5). The time course of the transient ΔSI (peak at 7.9 ± 0.4 s after each contraction, decay with half‐time of 4.6 ± 0.6 s) was comparable to the time course of the transient increase in relative heme saturation (13 ± 2 %, n = 5) measured after single contractions in another group of subjects by near‐infrared spectroscopy (peak at 9.3 ± 0.5 s, decay with half‐time 6.2 ± 0.8 s, n = 8). Simulations of intravascular and extravascular blood‐oxygenation level‐dependent (BOLD) effects in muscle suggested that intravascular BOLD makes a major contribution to the transient changes, although other factors such as increased vascular volume or increased muscle cell T2 may also contribute. The transients can be exploited for muscle functional imaging analogous to BOLD‐based brain functional imaging, and might provide an index of peripheral vascular function. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citation
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationCarlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Muller, M. D., Li, Z., Sica, C. T., Luck, J. C., Gao, Z., Blaha, C. A., Cauffman, A. E., Ross, A. J., Winkler, N. J. R., Herr, M. D., et al. (2016) · Physiological Reports · doi:10.14814/phy2.13004 · Cited by 28
Metadata
- Authors
- Meyer, R. A., Towse, T. F., Reid, R. W., Jayaraman, R. C., Wiseman, R. W., & McCully, K. K.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2004-09-22
- Volume
- 17
- Issue
- 6
- Pages
- 392-398
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2083021082
- Cited by
- 76
- References
- 2
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BOLD MRI mapping of transient hyperemia in skeletal muscle after single contractions. https://app.cochat.ai/papers/10.1002/nbm.893
- The paper
- Meyer, R. A., Towse, T. F., Reid, R. W., Jayaraman, R. C., Wiseman, R. W., & McCully, K. K. (2004). BOLD MRI mapping of transient hyperemia in skeletal muscle after single contractions. NMR in Biomedicine. https://doi.org/10.1002/nbm.893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.