Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record.

Comparison of HR MAS MR spectroscopic profiles of breast cancer tissue with clinical parameters

Sitter, Beathe, Lundgren, Steinar, Bathen, Tone F., Halgunset, Jostein, Fjosne, Hans E., Gribbestad, Ingrid S.·2006·NMR in Biomedicine

Abstract

Breast cancer is the most frequent form of cancer in women and improved diagnostic methods are desirable. Malignant cells have altered metabolism and metabolic mapping might become a tool in cancer diagnostics. High‐resolution magic angle spinning (HR MAS) MR spectroscopy of tissue biopsies provides detailed information on metabolic composition. The 600 MHz 1 H HR MAS spectra were acquired of breast cancer tissue from 85 patients and adjacent non‐involved tissue from 18 of these patients. Tissue specimens were investigated by microscopy after MR analysis. The resulting spectra were examined by three different approaches. Relative intensities of glycerophosphocholine (GPC), phosphocholine (PC) and choline were compared for cancerous and non‐involved specimens. Eight metabolites, choline, creatine, β‐glucose, GPC, glycine, myo‐inositol, PC and taurine, were quantified from the recorded spectra and compared with tumor histological type and size, patient's lymph node status and tissue composition of sample. The spectra were also compared with tumor histological type and size, lymph node status and tissue composition of samples using principal component analysis (PCA). Tumor samples could be distinguished from non‐involved samples (82% sensitivity, 100% specificity) based on relative intensities of signals from GPC, PC and choline in 1 H HR MAS spectra. Tissue concentrations of metabolites showed few differences between groups of samples, which can be caused by limitations in the quantification procedure. Choline and glycine concentrations were found to be significantly higher in tumors larger than 2 cm compared with smaller tumors. PCA of MAS spectra from patients with invasive ductal carcinomas indicated a possible prediction of spread to axillary lymph nodes. Metabolite estimates and PCA of MAS spectra were influenced by the percentage of tumor cells in the investigated specimens. Copyright © 2005 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.992

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Sitter, B., Lundgren, S., Bathen, T. F., Halgunset, J., Fjosne, H. E., & Gribbestad, I. S.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2005-10-17
Volume
19
Issue
1
Pages
30-40
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2092155681
Cited by
236
References
0
FWCI
2.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of HR MAS MR spectroscopic profiles of breast cancer tissue with clinical parameters. https://app.cochat.ai/papers/10.1002/nbm.992
The paper
Sitter, B., Lundgren, S., Bathen, T. F., Halgunset, J., Fjosne, H. E., & Gribbestad, I. S. (2006). Comparison of HR MAS MR spectroscopic profiles of breast cancer tissue with clinical parameters. NMR in Biomedicine. https://doi.org/10.1002/nbm.992

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.