Computer‐aided interpretation of mass spectra
The DOI matches its Crossref record.
Abstract
A system is described in which computer techniques are used to carry out major steps in the procedure for interpretation of high‐resolution mass spectral data. These steps include identification and evaluation of the molecular ion, neutral fragments lost from the molecular ion, and characteristic ion series, followed by elucidation of specific structural details using a sub‐routine for the particular compound class selected. The technique shows promise of not only increasing the interpreter's efficiency, but of providing more specific and detailed structural information from the spectral data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kind, T., & Fiehn, O. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-105 · Cited by 1,201
Metabolomics by Gas Chromatography–Mass Spectrometry: Combined Targeted and Untargeted Profiling
Fiehn, O. (2016) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb3004s114 · Cited by 917
Systematic classification of unknown metabolites using high-resolution fragmentation mass spectra
Dührkop, K., Nothias, L.-F., Fleischauer, M., Reher, R., Ludwig, M., Hoffmann, M. A., Petras, D., Gerwick, W. H., Rousu, J., Dorrestein, P. C., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0740-8 · Cited by 860
Identification of mass spectra by computer-searching a file of known spectra
Hertz, H. S., Hites, R. A., & Biemann, K. (1971) · Analytical Chemistry · doi:10.1021/ac60301a009 · Cited by 305
Mass Spectrometry in Organic Geochemistry
Burlingame, A. L., & Schnoes, H. K. (1969) · Organic Geochemistry · doi:10.1007/978-3-642-87734-6_4 · Cited by 240
Metabolite identification and molecular fingerprint prediction through machine learning
Heinonen, M., Shen, H., Zamboni, N., & Rousu, J. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts437 · Cited by 189
Computational mass spectrometry for small molecules
Scheubert, K., Hufsky, F., & Böcker, S. (2013) · Journal of Cheminformatics · doi:10.1186/1758-2946-5-12 · Cited by 173
“Already in 1969, Venkataraghavan et al [157] presented an automated approach “to identify the general nature of the compound and its functional groups.”
Metadata
- Authors
- Venkataraghavan, R., McLafferty, F. W., & van Lear, G. E.
- Venue
- Organic Mass Spectrometry
- Publisher
- Wiley
- Published
- 1969-01
- Volume
- 2
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0030-493X (ISSN-L)
- OpenAlex
- W2144638109
- Cited by
- 48
- References
- 0
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.