The DOI matches its Crossref record.
The ‘infinity cell’: A new trapped‐ion cell with radiofrequency covered trapping electrodes for fourier transform ion cyclotron resonance mass spectrometry
Abstract
The excitation event in Fourier transform ion cyclotron resonance mass spectrometry is optimized in order to obtain more reliable relative signal intensities and enhance the ion‐selection performance in multi‐tandem mass spectrometric experiments. Standard trapped‐ion cells suffer from the undesirable ejection of ions along the symmetry axis (z‐axis) of the cell, which is oriented parallel to the magnetic field lines. This z‐eiection effect is difficult to predict, and thus difficult to avoid, especially when complicated broad‐band excitation schemes are applied to the ions. An improved trapped‐ion cell design, referred to as the ‘Infinity Cell’, is discussed which eliminates z‐ejection. The Infinity Cell concept is based on the finding that it is possible to model the electric excitation field of an infinitely long cell with a cell of finite dimensions. The virtual elimination of z‐ejection effects is demonstrated in several suitable experiments by comparing the operation of the standard cell and the Infinity Cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Biogenic metallic elements in the human brain?
Everett, J., Lermyte, F., Brooks, J., Tjendana-Tjhin, V., Plascencia-Villa, G., Hands-Portman, I., Donnelly, J. M., Billimoria, K., Perry, G., Zhu, X., et al. (2021) · Science Advances · doi:10.1126/sciadv.abf6707 · Cited by 94
Standard Proteoforms and Their Complexes for Native Mass Spectrometry
Schachner, L. F., Ives, A. N., McGee, J. P., Melani, R. D., Kafader, J. O., Compton, P. D., Patrie, S. M., & Kelleher, N. L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02191-w · Cited by 48
The elliptical Penning trap: experimental investigations and simulations
Breitenfeldt, M., Baruah, S., Blaum, K., Herlert, A., Kretzschmar, M., Martinez, F., Marx, G., Schweikhard, L., & Walsh, N. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.05.008 · Cited by 19
Metadata
- Authors
- Caravatti, P., & Allemann, M.
- Venue
- Organic Mass Spectrometry
- Publisher
- Wiley
- Published
- 1991-05
- Volume
- 26
- Issue
- 5
- Pages
- 514-518
- ISSN
- 0030-493X (ISSN-L)
- OpenAlex
- W2069031182
- Cited by
- 385
- References
- 0
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The ‘infinity cell’: A new trapped‐ion cell with radiofrequency covered trapping electrodes for fourier transform ion cyclotron resonance mass spectrometry. https://app.cochat.ai/papers/10.1002/oms.1210260527
- The paper
- Caravatti, P., & Allemann, M. (1991). The ‘infinity cell’: A new trapped‐ion cell with radiofrequency covered trapping electrodes for fourier transform ion cyclotron resonance mass spectrometry. Organic Mass Spectrometry. https://doi.org/10.1002/oms.1210260527
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.