Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 341

The DOI matches its Crossref record.

Comparison of Rolyan and Jamar dynamometers for measuring grip strength

Open access
Mathiowetz, Virgil·2002·Occupational Therapy International

Abstract

This study compared the Jamar and Rolyan hydraulic dynamometers to determine their concurrent validity with known weights as well as their inter‐instrument reliability and concurrent validity for measuring grip strength in a clinical setting. Thirty females and 30 males were tested on these two grip strength measurement devices using a repeated measure design. Results showed that the Jamar and Rolyan dynamometers have acceptable concurrent validity with known weights (that is, correlation coefficients were r ≥ 0.9994), excellent inter‐instrument reliability (that is, intraclass correlation coefficients ranged from 0.90 to 0.97) and strong concurrent validity (that is, no significant differences between dynamometers' scores). Data indicate that Jamar and Rolyan dynamometers measure grip strength equivalently and can be used interchangeably. Thus, therapists using the Rolyan dynamometer are justified in using published normative data, which were collected with the Jamar dynamometer. Copyright © 2002 Whurr Publishers Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/oti.165

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 341

Metadata

Authors
Mathiowetz, V.
Venue
Occupational Therapy International
Publisher
Wiley
Published
2002-08
Volume
9
Issue
3
Pages
201-209
ISSN
  • 0966-7903 (ISSN-L)
  • 1557-0703
OpenAlex
W2036269127
Cited by
341
References
0
FWCI
1.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Rolyan and Jamar dynamometers for measuring grip strength. https://app.cochat.ai/papers/10.1002/oti.165
The paper
Mathiowetz, V. (2002). Comparison of Rolyan and Jamar dynamometers for measuring grip strength. Occupational Therapy International. https://doi.org/10.1002/oti.165

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.