The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dye removal by a novel hydrogel‐clay nanocomposite with enhanced swelling properties
Abstract
Acrylamide (AAm)‐2‐acrylamide‐2‐methylpropanesulfonic acid sodium salt (AMPSNa) hydrogel and AAm‐AMPSNa/clay hydrogel nanocomposite having 10 w% clay was prepared by in situ copolymerization in aqueous solution in the presence of a crosslinking agent (N,N′‐methylenebisacrylamide (NMBA)). Swelling properties and kinetics of the hydrogel samples were investigated in water and aqueous solutions of the Safranine‐T (ST) and Brilliant Cresyl Blue (BCB) dyes. The swelling and diffusion parameters were also calculated in water and dye solutions. It was observed that the AAm‐AMPSNa/clay hydrogel nanocomposite exhibits improved swelling capacity compared with the AAm‐AMPSNa hydrogel. It was also found that the diffusion mechanisms show non‐Fickian character. Adsorption properties of the hydrogel samples in the aqueous solution of ST and BCB dyes were also investigated. Clay incorporation into the hydrogel structure increased not only the adsorption capacity but also the adsorption rate. Adsorption capacity values of the hydrogel nanocomposite were found to be 484.2 and 494.2 mg g−1 for the ST and BCB dyes, respectively. It was seen that the adsorption of dyes by the hydrogel nanocomposite completed in 10 min while the AAm‐AMPSNa hydrogel adsorbed dyes approximately in 90 min. Adsorption data of the samples were modelled by the pseudo‐first‐order and pseudo‐second‐order kinetic equations in order to investigate dye adsorption mechanism. It was found that the adsorption kinetics of hydrogel nanocomposite followed a pseudo‐second‐order model. Equilibrium isotherms were analyzed using the Langmuir and Freundlich isotherms. It was seen that the Langmuir model fits the adsorption data better than the Freundlich model. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The adsorption of gases on plane surfaces of glass, mica and platinum
Langmuir, I. (1918) · Journal of the American Chemical Society · doi:10.1021/ja02242a004 · Cited by 23,242
Cited by
Superabsorbent hydrogel composites and nanocomposites: A review
Kabiri, K., Omidian, H., Zohuriaan‐Mehr, M. J., & Doroudiani, S. (2011) · Polymer Composites · doi:10.1002/pc.21046 · Cited by 479
Advances in non-hygienic applications of superabsorbent hydrogel materials
Zohuriaan-Mehr, M. J., Omidian, H., Doroudiani, S., & Kabiri, K. (2010) · Journal of Materials Science · doi:10.1007/s10853-010-4780-1 · Cited by 403
Hydrogel applications for adsorption of contaminants in water and wastewater treatment
Van Tran, V., Park, D., & Lee, Y.-C. (2018) · Environmental Science and Pollution Research · doi:10.1007/s11356-018-2605-y · Cited by 398
Zhou, C., Wu, Q., Lei, T., & Negulescu, I. I. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.04.034 · Cited by 372
Wang, W., & Wang, A. (2010) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2010.01.020 · Cited by 358
Metadata
- Authors
- Kaşgöz, H., & Durmus, A.
- Venue
- Polymers for Advanced Technologies
- Publisher
- Wiley
- Published
- 2008-01-22
- Volume
- 19
- Issue
- 7
- Pages
- 838-845
- ISSN
- 1042-7147 (ISSN-L)
- 1099-1581
- OpenAlex
- W1984925620
- Cited by
- 204
- References
- 1
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.