Surface modification of cotton fabric with dual‐responsive PNIPAAm/chitosan nano hydrogel
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The present study deals with preparing stimuli‐responsive poly N‐isopropyl acryl amide/chitosan (PNCS) nano hydrogel and looks into their effects as a surface modifying system of cotton fabric. The semi‐batch surfactant‐free emulsion polymerization method was proposed to reduce the size of particle and synthesis of PNCS nano particles. Fourier transform infrared, nuclear magnetic resonance, differential scanning calorimetry, scanning electron microscopy and dynamic light scattering methods confirmed the nano size of synthesized PNCS particles and sensitivity of these nano particles to the different temperature and pH, respectively. The water retention capacity (WRC) and carboxyl content of modified cotton with PNCS nano particles were assessed through the central composite design. The bounded PNCS nano particles to the surface of cotton fabrics made them responsive to these dual stimuli. The results demonstrated the dual effect of BTCA amount on WRC. Increase of the amount of BTCA itself led to the decrease of the WRC of modified cotton, but in the presence of PNCS, WRC was significantly increased. Copyright © 2013 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Cited by
Review of Stimuli-Responsive Polymers in Drug Delivery and Textile Application
CHATTERJEE, S., & Chi-leung HUI, P. (2019) · Molecules · doi:10.3390/molecules24142547 · Cited by 201
“The thermo-responsive nano-hydrogel made of pNIPAAm and chitosan was applied on cotton fabric as a surface modifying system and the nanohydrogel also showed pH-responsiveness [113].”
MethodChatterjee, S., Hui, P. C.-L., & Kan, C.-W. (2018) · Polymers · doi:10.3390/polym10050480 · Cited by 196
“The use of nanohydrogels with BTCA enhanced the water retention capacity of cotton fabric [162].”
MethodFunctionalized Textile Based Therapy for the Treatment of Atopic Dermatitis
Wang, W., Hui, P., & Kan, C.-W. (2017) · Coatings · doi:10.3390/coatings7060082 · Cited by 22
“The application of PNIPAAm combined with chitosan can make textiles with thermal/pH dual-responsive properties [140].”
Background
Metadata
- Authors
- Bashari, A., Hemmatinejad, N., & Pourjavadi, A.
- Venue
- Polymers for Advanced Technologies
- Publisher
- Wiley
- Published
- 2013-05-23
- Volume
- 24
- Issue
- 9
- Pages
- 797-806
- ISSN
- 1042-7147 (ISSN-L)
- 1099-1581
- OpenAlex
- W2143634523
- Cited by
- 46
- References
- 1
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.