Trace Determination of Lead, Chromium and Cadmium in Herbal Medicines Using Ultrasound‐Assisted Emulsification Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Introduction: The World Health Organization (WHO) recommends that medicinal plants should be checked for the presence of heavy metals. A preconcentration and separation technique for trace amounts of heavy metals from plant matrix is necessary in order to increase the sensitivity and precision of their determination. Objective: Lead, chromium and cadmium contaminations in herbal medicines were monitored using ultrasound‐assisted emulsification microextraction (USAEME) combined with graphite furnace atomic absorption spectrometry (GF–AAS). Methods: In this work, the metal ions in the aqueous solution were complexed with ammonium pyrrolidine dithiocarbamate (APDC) and were extracted into 45 μL of toluene that was sonically dispersed in the aqueous phase. The emulsion formed was centrifuged and 20 μL of separated toluene was injected into a GF–AAS for analysis. Several factors including the kind of extraction solvent and its volume, sample pH, ionic strength and concentration of APDC were optimised. Results: The linear dynamic range (LDR) values were in the range of 0.05 to 20 µg/L and the limit of detection values were in the range of 0.002–0.03 µg/L for target heavy metals. Enrichment factors were obtained in the range of 70–500. The precision of the proposed method was ≤8% (n = 5). The obtained amounts of Pb, Cr and Cd in selected herbal medicines were in the standard range, according to the WHO reports. Conclusion: The USAEME with GF–AAS procedure was shown to be an efficient, rapid, inexpensive and eco‐friendly method for the determination of lead, chromium and cadmium in herbal medicines. Application of the USAEME method leads to an increased extraction efficiency with satisfactory precision in a short time using an extraction solvent volume at the microlitre level. Copyright © 2015 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971 · cited 1×
“This can reduce the efficiency of the emulsification process because ultrasound waves can be absorbed and dispersed in viscous media (Assadi et al., 2010; Rezaee et al., 2010).”
BackgroundSelf-citation
Cited by
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“03 mg L¡1 (1279) Cd, Cu Hair IL-DLLME FAAS 0.”
Sadeghi, M., Rostami, E., Kordestani, D., Veisi, H., & Shamsipur, M. (2017) · RSC Advances · doi:10.1039/c6ra26025j · Cited by 28
Elik, A., Karakoy, T., Çilesiz, Y., & Altunay, N. (2021) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-020-02009-7 · Cited by 6
Metadata
- Authors
- Aghamohammadi, M., Faraji, M., Shahdousti, P., Kalhor, H., & Saleh, A.
- Venue
- Phytochemical Analysis
- Publisher
- Wiley
- Published
- 2015-01-09
- Volume
- 26
- Issue
- 3
- Pages
- 209-214
- ISSN
- 0958-0344 (ISSN-L)
- 1099-1565
- OpenAlex
- W1513706433
- Cited by
- 34
- References
- 1
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trace Determination of Lead, Chromium and Cadmium in Herbal Medicines Using Ultrasound‐Assisted Emulsification Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry. https://app.cochat.ai/papers/10.1002/pca.2554
- The paper
- Aghamohammadi, M., Faraji, M., Shahdousti, P., Kalhor, H., & Saleh, A. (2015). Trace Determination of Lead, Chromium and Cadmium in Herbal Medicines Using Ultrasound‐Assisted Emulsification Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry. Phytochemical Analysis. https://doi.org/10.1002/pca.2554
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.