The DOI matches its Crossref record.
A microfluidics approach for the isolation of nucleated red blood cells (NRBCs) from the peripheral blood of pregnant women
Open accessAbstract
Objective: Nucleated red blood cells (NRBCs) have been identified in maternal circulation and potentially provide a resource for the monitoring and diagnosis of maternal, fetal, and neonatal health and disease. Past strategies used to isolate and enrich for NRBCs are limited to complex approaches that result in low recovery and less than optimal cell purity. Here we report the development of a high‐throughput and highly efficient microfluidic device for isolating rare NRBCs from maternal blood. Material and Methods: NRBCs were isolated from the peripheral blood of 58 pregnant women using a microfluidic process that consists of a microfluidic chip for size‐based cell separation and a magnetic device for hemoglobin‐based cell isolation. Results: The microfluidic–magnetic combination removes nontarget red blood cells and white blood cells at a very high efficiency (∼99.99%). The device successfully identified NRBCs from the peripheral blood of 58/58 pretermination samples with a mean of 37.44 NRBC/mL (range 0.37–274.36 NRBC/mL). These results were compared with those from previous studies. Conclusion: The microfluidic device results in an approximate 10‐ to 20‐fold enrichment of NRBCs over methods described previously. The reliability of isolation and the purity of the NRBC product have the potential to enable the subsequent application of molecular diagnostic assays. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Self-citationWyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Single-cell RNA-seq: advances and future challenges
Saliba, A.-E., Westermann, A. J., Gorski, S. A., & Vogel, J. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku555 · Cited by 847
“Recent advances in engineering have allowed researchers to go beyond using molecular markers by specifying cells based on physiological and biophysical features such as cell size (69), deformation (70,71), and electric (72) or magnetic properties (73).”
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Metadata
- Authors
- Huang, R., Barber, T. A., Schmidt, M. A., Tompkins, R. G., Toner, M., Bianchi, D. W., Kapur, R., & Flejter, W. L.
- Venue
- Prenatal Diagnosis
- Publisher
- Wiley
- Published
- 2008-09-29
- Volume
- 28
- Issue
- 10
- Pages
- 892-899
- ISSN
- 0197-3851 (ISSN-L)
- 1097-0223
- OpenAlex
- W2112331560
- Cited by
- 158
- References
- 0
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfluidics approach for the isolation of nucleated red blood cells (NRBCs) from the peripheral blood of pregnant women. https://app.cochat.ai/papers/10.1002/pd.2079
- The paper
- Huang, R., Barber, T. A., Schmidt, M. A., Tompkins, R. G., Toner, M., Bianchi, D. W., Kapur, R., & Flejter, W. L. (2008). A microfluidics approach for the isolation of nucleated red blood cells (NRBCs) from the peripheral blood of pregnant women. Prenatal Diagnosis. https://doi.org/10.1002/pd.2079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.