CoChat

Natural Language Processing to identify pneumonia from radiology reports

Open access
Dublin, Sascha, Baldwin, Eric, Walker, Rod L., Christensen, Lee M., Haug, Peter J., Jackson, Michael L., Nelson, Jennifer C., Ferraro, Jeffrey, Carrell, David, Chapman, Wendy W. · 2013 · Pharmacoepidemiology and Drug Safety
Cited by 65

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: This study aimed to develop Natural Language Processing (NLP) approaches to supplement manual outcome validation, specifically to validate pneumonia cases from chest radiograph reports. Methods: We trained one NLP system, ONYX, using radiograph reports from children and adults that were previously manually reviewed. We then assessed its validity on a test set of 5000 reports. We aimed to substantially decrease manual review, not replace it entirely, and so, we classified reports as follows: (1) consistent with pneumonia; (2) inconsistent with pneumonia; or (3) requiring manual review because of complex features. We developed processes tailored either to optimize accuracy or to minimize manual review. Using logistic regression, we jointly modeled sensitivity and specificity of ONYX in relation to patient age, comorbidity, and care setting. We estimated positive and negative predictive value (PPV and NPV) assuming pneumonia prevalence in the source data. Results: Tailored for accuracy, ONYX identified 25% of reports as requiring manual review (34% of true pneumonias and 18% of non‐pneumonias). For the remainder, ONYX's sensitivity was 92% (95% CI 90–93%), specificity 87% (86–88%), PPV 74% (72–76%), and NPV 96% (96–97%). Tailored to minimize manual review, ONYX classified 12% as needing manual review. For the remainder, ONYX had sensitivity 75% (72–77%), specificity 95% (94–96%), PPV 86% (83–88%), and NPV 91% (90–91%). Conclusions: For pneumonia validation, ONYX can replace almost 90% of manual review while maintaining low to moderate misclassification rates. It can be tailored for different outcomes and study needs and thus warrants exploration in other settings. Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/pds.3418

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 65

Metadata

Authors
Dublin, S., Baldwin, E., Walker, R. L., Christensen, L. M., Haug, P. J., Jackson, M. L., Nelson, J. C., Ferraro, J., Carrell, D., & Chapman, W. W.
Venue
Pharmacoepidemiology and Drug Safety
Publisher
Wiley
Published
2013-04
Volume
22
Issue
8
Pages
834-841
ISSN
  • 1053-8569 (ISSN-L)
  • 1099-1557
OpenAlex
W1560862568
Cited by
65
References
2
FWCI
1.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.