Characterization and mechanical properties of poly(lactic acid)/poly(ϵ‐caprolactone)/organoclay nanocomposites prepared by melt compounding
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study investigates the preparation, characterization, and mechanical properties of nanocomposites prepared from poly(lactic acid) (PLA), an organoclay, hereafter referred to as Clay, and poly(ε‐caprolactone) (PCL) by melt compounding in a co‐rotating type, twin screw extruder. The molecular weight of the PCL used was 10K, 40K, or 70–100K. Tensile test data show that the Young's modulus of the PLA/Clay nanocomposite was about 19% higher than that of neat PLA. The tensile strength of the PLA/PCL(10K and 40K)/Clay nanocomposites was about 17% higher than that of neat PLA. On the other hand, the tensile strength of the PLA/PCL(70–100K)/Clay sample was about 7% lower than that of neat PLA. The elongation of the PLA/PCL/Clay composite also improved. The effect of d‐spacing, resulting from adding PCL to the PLA/Clay nanocomposite, depends on the molecular weight of the PCL. The size of the clay agglomerates in the PLA/PCL/Clay nanocomposites is larger than those found in the PLA/Clay. Furthermore, the thermal stability of the PLA/Clay nanocomposite increases with the addition of PCL. On the whole, PCL(10K) was found to be the best additive for PLA/Clay nanocomposites. POLYM. ENG. SCI. 46:1001–1007, 2006. © 2006 Society of Plastics Engineers
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New polylactide/layered silicate nanocomposites. 1. Preparation, characterization, and properties
Sinha Ray, S., Maiti, P., Okamoto, M., Yamada, K., & Ueda, K. (2002) · Macromolecules · doi:10.1021/ma011613e · Cited by 607
Cited by
Nano-biocomposites: Biodegradable polyester/nanoclay systems
BORDES, P., POLLET, E., & AVEROUS, L. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.10.002 · Cited by 1,033
Research progress in toughening modification of poly(lactic acid)
Liu, H., & Zhang, J. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22283 · Cited by 767
Multifunctional nanostructured PLA materials for packaging and tissue engineering
Armentano, I., Bitinis, N., Fortunati, E., Mattioli, S., Rescignano, N., Verdejo, R., Lopez-Manchado, M. A., & Kenny, J. M. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.05.010 · Cited by 645
Structuration, selective dispersion and compatibilizing effect of (nano)fillers in polymer blends
Taguet, A., Cassagnau, P., & Lopez-Cuesta, J.-M. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.04.002 · Cited by 572
Toughening modification of PLLA/PBS blends via in situ compatibilization
Wang, R., Wang, S., Zhang, Y., Wan, C., & Ma, P. (2009) · Polymer Engineering & Science · doi:10.1002/pen.21210 · Cited by 266
Metadata
- Authors
- Hasook, A., Tanoue, S., Iemoto, Y., & Unryu, T.
- Venue
- Polymer Engineering & Science
- Publisher
- Wiley
- Published
- 2006-06-21
- Volume
- 46
- Issue
- 8
- Pages
- 1001-1007
- ISSN
- 0032-3888 (ISSN-L)
- 1548-2634
- OpenAlex
- W2004185077
- Cited by
- 71
- References
- 1
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.