The DOI matches its Crossref record.
Analysis of degradation mechanisms of crystalline silicon PV modules after 12 years of operation in Southern Europe
Abstract
The long‐term reliability of photovoltaic modules is crucial to ensure the technical and economic viability of PV as a successful energy source. The analysis of degradation mechanisms of PV modules is key to ensure current lifetimes exceeding 25 years. This paper presents the results of the investigations carried out on the degradation mechanisms of a crystalline silicon PV installation of 2 kWp after 12 years of exposure in Málaga, Spain. The analysis was conducted by visual inspection, infrared thermography and electrical performance evaluation. By visual inspection, the most relevant defects in the modules were identified and ranked according to their frequency. The electrical performance was assessed by comparing the characteristic parameters of the individual modules, obtained by outdoor measurements at the start and end of the exposure period. The correlation of the visual defects and the shifts in the electrical parameters was analysed. The results presented show that glass weathering, delamination at the cell‐EVA interface and oxidation of the antireflective coating and the cell metallization grid were the most frequently occurring defects found. The total peak power loss, including the initial light induced degradation, was 11.5%, which corresponded almost totally to a loss in short‐circuit current. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photovoltaic Degradation Rates—an Analytical Review
Jordan, D. C., & Kurtz, S. R. (2013) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.1182 · Cited by 1,529
Peng, J., Lu, L., & Yang, H. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.035 · Cited by 772
Compendium of photovoltaic degradation rates
Jordan, D. C., Kurtz, S. R., VanSant, K., & Newmiller, J. (2016) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.2744 · Cited by 556
Performance assessment and degradation analysis of solar photovoltaic technologies: A review
Kumar, M., & Kumar, A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.083 · Cited by 301
Metadata
- Authors
- Sánchez‐Friera, P., Piliougine, M., Peláez, J., Carretero, J., & Sidrach de Cardona, M.
- Venue
- Progress in Photovoltaics: Research and Applications
- Publisher
- Wiley
- Published
- 2011-01-05
- Volume
- 19
- Issue
- 6
- Pages
- 658-666
- ISSN
- 1062-7995 (ISSN-L)
- 1099-159X
- OpenAlex
- W2171441250
- Cited by
- 244
- References
- 0
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of degradation mechanisms of crystalline silicon PV modules after 12 years of operation in Southern Europe. https://app.cochat.ai/papers/10.1002/pip.1083
- The paper
- Sánchez‐Friera, P., Piliougine, M., Peláez, J., Carretero, J., & Sidrach de Cardona, M. (2011). Analysis of degradation mechanisms of crystalline silicon PV modules after 12 years of operation in Southern Europe. Progress in Photovoltaics: Research and Applications. https://doi.org/10.1002/pip.1083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.