Performance ratio revisited: is PR > 90% realistic?
Open accessAbstract
In this study, we investigate the performance ratio (PR) of about 100 German photovoltaic system installations. Monitored PR is found to be systematically lower by ~2–4% when calculated with irradiation data obtained by pyranometers (henceforth denoted as PRPyr) as compared with irradiation amounts measured by reference cells (denoted as PRSi). Annual PRSi for the ~100 systems is found to be between ~70% and ~90% for the year 2010, with a median PR of ~84%. Next, simulations were performed to determine loss mechanisms of the top 10 performing systems, revealing a number of these loss mechanisms may still allow for some optimization. Despite the fact that we do not see such values from our monitoring data base up to now, we believe PRSi values above 90% are realistic even today, using today's commercially available components, and should be expected more frequently in the future. This contribution may help in deepening our knowledge on both energy loss mechanisms and efficiency limits on the system level and standardization processes of system‐related aspects. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flat-plate PV-Thermal collectors and systems: A review
Zondag, H. A. (2007) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2005.12.012 · Cited by 679
Regional PV power prediction for improved grid integration
Lorenz, E., Scheidsteger, T., Hurka, J., Heinemann, D., & Kurz, C. (2011) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.1033 · Cited by 292
Monitoring and remote failure detection of grid-connected PV systems based on satellite observations
Drews, A., de Keizer, A. C., Beyer, H. G., Lorenz, E., Betcke, J., van Sark, W. G. J. H. M., Heydenreich, W., Wiemken, E., Stettler, S., Toggweiler, P., et al. (2007) · Solar Energy · doi:10.1016/j.solener.2006.06.019 · Cited by 279
Self-citationDecker, B., & Jahn, U. (1997) · Solar Energy · doi:10.1016/s0038-092x(96)00132-6 · Cited by 142
Uncertainty in Photovoltaic performance parameters – dependence on location and material
Strobel, M., Betts, T. R., Friesen, G., Beyer, H. G., & Gottschalg, R. (2009) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2009.02.003 · Cited by 43
Cited by
Hoppmann, J., Volland, J., Schmidt, T. S., & Hoffmann, V. H. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.068 · Cited by 531
Bhandari, K. P., Collier, J. M., Ellingson, R. J., & Apul, D. S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.02.057 · Cited by 459
An integrated review of factors influencing the perfomance of photovoltaic panels
Fouad, M. M., Shihata, L. A., & Morgan, E. I. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.141 · Cited by 451
van der Kam, M., & van Sark, W. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.04.092 · Cited by 341
Self-citationField experience and performance analysis of floating PV technologies in the tropics
Liu, H., Krishna, V., Lun Leung, J., Reindl, T., & Zhao, L. (2018) · Progress in Photovoltaics: Research and Applications · doi:10.1002/pip.3039 · Cited by 306
Metadata
- Authors
- Reich, N. H., Mueller, B., Armbruster, A., van Sark, W. G. J. H. M., Kiefer, K., & Reise, C.
- Venue
- Progress in Photovoltaics: Research and Applications
- Publisher
- Wiley
- Published
- 2012-01-18
- Volume
- 20
- Issue
- 6
- Pages
- 717-726
- ISSN
- 1062-7995 (ISSN-L)
- 1099-159X
- OpenAlex
- W2131615404
- Cited by
- 254
- References
- 5
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.