Extraction and separation of Cd and Te from cadmium telluride photovoltaic manufacturing scrap
The DOI matches its Crossref record.
Abstract
The extraction and separation of cadmium, tellurium, and copper from CdTe PV module scrap was investigated. Several leaching technologies were assessed and the extraction of CdTe from samples of PV modules was optimized for maximum efficiency and minimum cost. A dilute aqueous solution of hydrogen peroxide and sulfuric acid was sufficient to completely leach out cadmium and tellurium from these samples. The same method successfully removed cadmium and tellurium from actual manufacturing scrap; copper was partially extracted. Subsequently, cation-exchange resins were used to separate cadmium and copper from tellurium. Complete separation (i.e., 99·99%) of Cd from Te was accomplished. The estimated costs of these processes for 10 MW/year processing are about 2 cents per W. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An overview of solar photovoltaic panels’ end-of-life material recycling
Chowdhury, M. S., Rahman, K. S., Chowdhury, T., Nuthammachot, N., Techato, K., Akhtaruzzaman, M., Tiong, S. K., Sopian, K., & Amin, N. (2020) · Energy Strategy Reviews · doi:10.1016/j.esr.2019.100431 · Cited by 785
Sustainability of photovoltaics: The case for thin-film solar cells
Fthenakis, V. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2009.05.001 · Cited by 443
Self-citationReview on feasible recycling pathways and technologies of solar photovoltaic modules
Tao, J., & Yu, S. (2015) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2015.05.005 · Cited by 356
Recycling of photovoltaic panels by physical operations
Granata, G., Pagnanelli, F., Moscardini, E., Havlik, T., & Toro, L. (2014) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2014.01.012 · Cited by 280
A novel approach for the recycling of thin film photovoltaic modules
Berger, W., Simon, F.-G., Weimann, K., & Alsema, E. A. (2010) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2009.12.001 · Cited by 231
End-of-life photovoltaic modules: a systematic quantitative literature review
Mahmoudi, S., Huda, N., Alavi, Z., Islam, M. T., & Behnia, M. (2019) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2019.03.018 · Cited by 226
Recycling paths for thin-film chalcogenide photovoltaic waste – Current feasible processes
Marwede, M., Berger, W., Schlummer, M., Mäurer, A., & Reller, A. (2013) · Renewable Energy · doi:10.1016/j.renene.2012.12.038 · Cited by 160
Future recycling flows of tellurium from cadmium telluride photovoltaic waste
Marwede, M., & Reller, A. (2012) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2012.09.003 · Cited by 159
“Several processes to recover CdTe from CdTe-PV modules were developed on the lab- and demonstration-scale (Berger et al., 2010; Bohland et al., 2002; Campo et al., 2003; DeFilippo, 2011; Fthenakis and Wang, 2006; Goozner et al., 1999; Kernbaum, 2011; Palitzsch, 2010).”
BackgroundEcological and human health risk assessment of metals leached from end-of-life solar photovoltaics
Nain, P., & Kumar, A. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.115393 · Cited by 90
Metadata
- Authors
- Fthenakis, V. M., & Wang, W.
- Venue
- Progress in Photovoltaics: Research and Applications
- Publisher
- Wiley
- Published
- 2006
- Volume
- 14
- Issue
- 4
- Pages
- 363-371
- ISSN
- 1062-7995 (ISSN-L)
- 1099-159X
- OpenAlex
- W2101255903
- Cited by
- 86
- References
- 0
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.