The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Antibody microarrays: An evaluation of production parameters
Abstract
Antibody microarrays could have an enormous impact on the functional analysis of cellular activity and regulation, especially at the level of protein expression and protein‐protein interaction, and might become an invaluable tool in disease diagnostics. The array surface is bound to have a tremendous influence on the findings from such studies. Apart from the basic issue of how to attach antibodies optimally without affecting their function, it is also important that the cognate antigens, applied within a complex protein mixture, all bind to the arrayed antibodies irrespective of their enormous variety in structure. In this study, various factors in the production of antibody microarrays on glass support were analysed: the modification of the glass surface; kind and length of cross‐linkers; composition and pH of the spotting buffer; blocking reagents; antibody concentration and storage procedures, in order to evaluate their effect on array performance. Altogether, data from more than 700 individual array experiments were taken into account. In addition to home‐made slides, commercially available systems were also included in the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correlation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Printing Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Haab, B. B., Dunham, M. J., & Brown, P. O. (2001) · Genome Biology · doi:10.1186/gb-2001-2-2-research0004 · Cited by 892
Analysis of yeast protein kinases using protein chips
Zhu, H., Klemic, J. F., Chang, S., Bertone, P., Casamayor, A., Klemic, K. G., Smith, D., Gerstein, M., Reed, M. A., & Snyder, M. (2000) · Nature Genetics · doi:10.1038/81576 · Cited by 797
Autoantigen microarrays for multiplex characterization of autoantibody responses
Robinson, W. H., DiGennaro, C., Hueber, W., Haab, B. B., Kamachi, M., Dean, E. J., Fournel, S., Fong, D., Genovese, M. C., De Vegvar, H. E. N., et al. (2002) · Nature Medicine · doi:10.1038/nm0302-295 · Cited by 673
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Richards, A. B., Krakowka, S., Dexter, L. B., Schmid, H., Wolterbeek, A. P. M., Waalkens-Berendsen, D. H., Shigoyuki, A., & Kurimoto, M. (2002) · Food and Chemical Toxicology · doi:10.1016/s0278-6915(02)00011-x · Cited by 593
Printing Small Molecules as Microarrays and Detecting Protein−Ligand Interactions en Masse
MacBeath, G., Koehler, A. N., & Schreiber, S. L. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991083q · Cited by 420
Bhatia, S. K., Shriver-Lake, L. C., Prior, K. J., Georger, J. H., Calvert, J. M., Bredehorst, R., & Ligler, F. S. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90662-3 · Cited by 365
Cleland, J. L., Lam, X., Kendrick, B., Yang, J., Yang, T., Overcashier, D., Brooks, D., Hsu, C., & Carpenter, J. F. (2001) · Journal of Pharmaceutical Sciences · doi:10.1002/1520-6017(200103)90:3<310::aid-jps6>3.0.co;2-r · Cited by 299
Protein and antibody arrays and their medical applications
Cahill, D. J. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00325-8 · Cited by 288
A microarray enzyme-linked immunosorbent assay for autoimmune diagnostics
Joos, T. O., Schrenk, M., Höpfl, P., Kröger, K., Chowdhury, U., Stoll, D., Schörner, D., Dürr, M., Herick, K., Rupp, S., et al. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000701)21:13<2641::aid-elps2641>3.0.co;2-5 · Cited by 280
Lilley, K. S., Razzaq, A., & Dupree, P. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(01)00275-7 · Cited by 269
Solid Supports in Enzyme-Linked Immunosorbent Assay and Other Solid-Phase Immunoassays
Butler, J. E. (2000) · Methods · doi:10.1006/meth.2000.1031 · Cited by 257
Proteomics: Capacityversus utility
Harry, J. L., Wilkins, M. R., Herbert, B. R., Packer, N. H., Gooley, A. A., & Williams, K. L. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1071::aid-elps1071>3.0.co;2-m · Cited by 162
Karsten, S. L. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.2.e4 · Cited by 158
Lessons from metabolic engineering for functional genomics and drug discovery
Bailey, J. E. (1999) · Nature Biotechnology · doi:10.1038/10794 · Cited by 152
Proteomics: a technology-driven and technology-limited discovery science
Lee, K. H. (2001) · Trends in biotechnology · doi:10.1016/s0167-7799(01)01639-0 · Cited by 128
Protein based microarrays: A tool for probing the proteome of cancer cells and tissues
Madoz‐Gúrpide, J., Wang, H., Misek, D. E., Brichory, F., & Hanash, S. (2001) · PROTEOMICS · Cited by 122
Functional Genomics: High-Throughput mRNA, Protein, and Metabolite Analyses
Oliver, D. J., Nikolau, B. J., & Wurtele, E. S. (2002) · Metabolic Engineering · doi:10.1006/mben.2001.0212 · Cited by 111
Protein functions and biological contexts
Miklos, G. L. G., & Maleszka, R. (2001) · PROTEOMICS · doi:10.1002/1615-9861(200102)1:2<169::aid-prot169>3.0.co;2-c · Cited by 107
Stability of monoclonal IgM antibodies freeze-dried in the presence of trehalose
Dráber, P., Dráberová, E., & Nováková, M. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)00326-r · Cited by 65
Cited by
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Chemical Strategies for Generating Protein Biochips
Jonkheijm, P., Weinrich, D., Schröder, H., Niemeyer, C. M., & Waldmann, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200801711 · Cited by 590
Vashist, S. K., Lam, E., Hrapovic, S., Male, K. B., & Luong, J. H. T. (2014) · Chemical Reviews · doi:10.1021/cr5000943 · Cited by 345
Progress in protein and antibody microarray technology
Angenendt, P. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03392-1 · Cited by 289
Hall, D. A., Ptacek, J., & Snyder, M. (2007) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2006.11.021 · Cited by 286
Metadata
- Authors
- Kusnezow, W., Jacob, A., Walijew, A., Diehl, F., & Hoheisel, J. D.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 3
- Issue
- 3
- Pages
- 254-264
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2035812229
- Cited by
- 299
- References
- 23
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.