The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Label‐free detection methods for protein microarrays
Abstract
With the growth of the “‐omics” such as functional genomics and proteomics, one of the foremost challenges in biotechnologies has become the development of novel methods to monitor biological process and acquire the information of biomolecular interactions in a systematic manner. To fully understand the roles of newly discovered genes or proteins, it is necessary to elucidate the functions of these molecules in their interaction network. Microarray technology is becoming the method of choice for such a task. Although protein microarray can provide a high throughput analytical platform for protein profiling and protein‐protein interaction, most of the current reports are limited to labeled detection using fluorescence or radioisotope techniques. These limitations deflate the potential of the method and prevent the technology from being adapted in a broader range of proteomics applications. In recent years, label‐free analytical approaches have gone through intensified development and have been coupled successfully with protein microarray. In many examples of label‐free study, the microarray has not only offered the high throughput detection in real time, but also provided kinetics information as well as in situ identification. This article reviews the most significant label‐free detection methods for microarray technology, including surface plasmon resonance imaging, atomic force microscope, electrochemical impedance spectroscopy and MS and their applications in proteomics research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Global Analysis of Protein Activities Using Proteome Chips
Zhu, H., Bilgin, M., Bangham, R., Hall, D., Casamayor, A., Bertone, P., Lan, N., Jansen, R., Bidlingmaier, S., Houfek, T., et al. (2001) · Science · doi:10.1126/science.1062191 · Cited by 1,884
Cited by
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,357
Carbon nanotubes as optical biomedical sensors
Kruss, S., Hilmer, A. J., Zhang, J., Reuel, N. F., Mu, B., & Strano, M. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.015 · Cited by 413
Popot, J.-L., Althoff, T., Bagnard, D., Banères, J.-L., Bazzacco, P., Billon-Denis, E., Catoire, L. J., Champeil, P., Charvolin, D., Cocco, M. J., et al. (2011) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-042910-155219 · Cited by 257
Metadata
- Authors
- Yu, X., Xu, D., & Cheng, Q.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2006-10
- Volume
- 6
- Issue
- 20
- Pages
- 5493-5503
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2142794584
- Cited by
- 191
- References
- 2
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.