How specific is my SRM?: The issue of precursor and product ion redundancy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Selected reaction monitoring (SRM) MS is proving to be a popular approach for targeted quantitative proteomics. The use of proteotypic peptides as candidates for SRM analysis is a wise first step in SRM method design. The obvious reason for this is the need to avoid redundancy at the sequence level, however this is incidental. The true reason is that homologous peptides result in redundancy in the mass‐to‐charge domain. This may seem like a trivial subtlety, however, we believe this is an issue of far greater significance than the proteomic community is aware. This VIEWPOINT article serves to highlight the complexity associated with designing SRM assays in light of potential ion redundancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · cited 1×
“The proteomic research community is enthusiastically embracing selected reaction monitoring (SRM) MS methods for targeted quantitative proteomic analysis [1–14].”
MethodQuantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230 · cited 1×
“Even with moderately adundant proteins in plasma, interferences have been reported following immunodepletion [7] and strong cation exchange (SCX) fractionation [10].”
Background
Cited by
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
“It has been discussed that, for SRM measurements, interference of contaminating transitions, incomplete tryptic cleavage, or possible modifications of a peptide or other such artifacts may impede the accuracy of quantification (39, 40).”
BackgroundPeterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
“transitions, are available to confirm the identity of the peptide (57, 58).”
BackgroundmProphet: automated data processing and statistical validation for large-scale SRM experiments
Reiter, L., Rinner, O., Picotti, P., Hüttenhain, R., Beck, M., Brusniak, M.-Y., Hengartner, M. O., & Aebersold, R. (2011) · Nature Methods · doi:10.1038/nmeth.1584 · Cited by 532
“3 ) signals from peptides, which have similar precursor masses and show residual ion current in the selected m/z window corresponding to the fragment ion (Q3) (ref”
BackgroundTargeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Vidova, V., & Spacil, Z. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.059 · Cited by 352
Metadata
- Authors
- Sherman, J., McKay, M. J., Ashman, K., & Molloy, M. P.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2009-02-27
- Volume
- 9
- Issue
- 5
- Pages
- 1120-1123
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W1993912669
- Cited by
- 144
- References
- 2
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How specific is my SRM?: The issue of precursor and product ion redundancy. https://app.cochat.ai/papers/10.1002/pmic.200800577
- The paper
- Sherman, J., McKay, M. J., Ashman, K., & Molloy, M. P. (2009). How specific is my SRM?: The issue of precursor and product ion redundancy. PROTEOMICS. https://doi.org/10.1002/pmic.200800577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.