Quantifying proteins by mass spectrometry: The selectivity of SRM is only part of the problem
Open accessThe DOI matches its Crossref record.
Abstract
Precise and accurate protein quantification is critical to many areas of proteomics. Antibody‐based approaches are costly and time‐consuming to develop, consequently, there is considerable interest in alternative quantitative methods that are versatile and can be implemented without the considerable delays associated with antibody development and characterization. Approaches based on MS have therefore attracted considerable attention and are now frequently touted as the most practical and powerful of all options. Nevertheless, there are serious limitations associated with quantifying a protein based on tandem mass analysis of one or two peptides generated by either chemical or enzymatic cleavage. In an accompanying Viewpoint article, Molloy and coworkers point out that selectivity is not necessarily guaranteed despite the power of SRM. Here we address an additional concern that can also compromise specificity. In complex mammalian systems, multiple proteins can serve as precursors of a single peptide and consequently, depending on the peptide(s) selected, protein levels may be significantly under‐ or overestimated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
“It has been discussed that, for SRM measurements, interference of contaminating transitions, incomplete tryptic cleavage, or possible modifications of a peptide or other such artifacts may impede the accuracy of quantification (39, 40).”
BackgroundPeterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
“transitions, are available to confirm the identity of the peptide (57, 58).”
BackgroundQuantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Selected reaction monitoring applied to proteomics
Gallien, S., Duriez, E., & Domon, B. (2011) · Journal of Mass Spectrometry · doi:10.1002/jms.1895 · Cited by 286
Mass spectrometry and 3‐nitrotyrosine: Strategies, controversies, and our current perspective
Tsikas, D., & Duncan, M. W. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21396 · Cited by 76
Self-citation
Metadata
- Authors
- Duncan, M. W., Yergey, A. L., & Patterson, S. D.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2009-02-27
- Volume
- 9
- Issue
- 5
- Pages
- 1124-1127
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2069720157
- Cited by
- 76
- References
- 0
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantifying proteins by mass spectrometry: The selectivity of SRM is only part of the problem. https://app.cochat.ai/papers/10.1002/pmic.200800739
- The paper
- Duncan, M. W., Yergey, A. L., & Patterson, S. D. (2009). Quantifying proteins by mass spectrometry: The selectivity of SRM is only part of the problem. PROTEOMICS. https://doi.org/10.1002/pmic.200800739
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.