Polymer NSR spectroscopy. II. The high resolution spectra of methyl methacrylate polymers prepared with free radical and anionic initiators
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Spectra of methyl methacrylate polymers in chloroform solution at 90° show three α‐methyl proton peaks. Measurements of their areas in spectra of polymers prepared with free radical and anionic initiators indicate that these may be attributed to (1) isotactic sequences (ddd or lll), (2) syndiotactic sequences (ldl or dld), and (3) heterotactic sequences (ldd, dll, ddl, or lld). The conformation and stereochemical configuration of the chains may thus be examined with considerable discrimination; degrees of regularity, block sizes, etc. appear to be determinable. Free radical polymers of methyl methacrylate are found to be predominantly syndiotactic, whereas those produced with anionic initiators. such as n‐butyllithium, are shown to be predominantly isotactic, in agreement with the findings of others. The backbone methylene resonance also shows striking changes with chain stereochemical configuration, such as to provide absolute, independent confirmation of the assigned structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRYSTALLINE POLYMERS OF METHYL METHACRYLATE
Fox, T. G., Garrett, B. S., Goode, W. E., Gratch, S., Kincaid, J. F., Spell, A., & Stroupe, J. D. (1958) · Journal of the American Chemical Society · doi:10.1021/ja01540a068 · Cited by 350
Scott, N. D., Walker, J. F., & Hansley, V. L. (1936) · Journal of the American Chemical Society · doi:10.1021/ja01303a022 · Cited by 224
Polymerization of methyl methacrylate initiated by an electron transfer to the monomer
Szwarc, M., & Rembaum, A. (1956) · Journal of Polymer Science · doi:10.1002/pol.1956.1202210025 · Cited by 90
Cited by
Selectivity in Propene Polymerization with Metallocene Catalysts
Resconi, L., Cavallo, L., Fait, A., & Piemontesi, F. (2000) · Chemical Reviews · doi:10.1021/cr9804691 · Cited by 1,398
Transition vitreuse dans les polymères amorphes. Etude phénoménologique
Kovacs, A. J. (2006) · Advances in Polymer Science · doi:10.1007/bfb0050366 · Cited by 1,026
Intrinsic viscosities and unperturbed dimensions of long chain molecules
Kurata, M., & Stockmayer, W. H. (1963) · Advances in Polymer Science · doi:10.1007/bfb0050490 · Cited by 726
Small, B. L., & Brookhart, M. (1999) · Macromolecules · doi:10.1021/ma981698s · Cited by 326
Satoh, K., & Kamigaito, M. (2009) · Chemical Reviews · doi:10.1021/cr900115u · Cited by 302
Metadata
- Authors
- Bovey, F. A., & Tiers, G. V. D.
- Venue
- Journal of Polymer Science
- Publisher
- Wiley
- Published
- 1960-05
- Volume
- 44
- Issue
- 143
- Pages
- 173-182
- ISSN
- 0022-3832 (ISSN-L)
- 1542-6238
- OpenAlex
- W4240637533
- Cited by
- 732
- References
- 3
- FWCI
- 44.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.