Molecular vibrations and structure of high polymers. II. Helical parameters of infinite polymer chains as functions of bond lengths, bond angles, and internal rotation angles
The DOI matches its Crossref record.
Abstract
Helical conformations of infinite polymer chains may be described by the helical parameters including ρ i (the distance of the i th atom from the helix axis), d ij (the translation along the axis), and θij (the angle of rotation about the axis on passing from the i th atom to the j th). For the polymer main chain (M)∞, (M 1M 2)∞, (M 1M 2M 3)∞, (M 1M 2M 3M 4)∞, (M 1M 2M 3M 4M 5)∞, (M 1M 2M 3M 4M 5M 6)∞ concise mathematical equations for the helical parameters are given in terms of the internal coordinates, such as the bond lengths, the bond angles, and the internal rotation angles. These equations are useful in calculating the internal coordinates and in selecting likely structure models from the helical parameters experimentally determined. The internal coordinates and helical parameters of polyethylene, polytetrafluoroethylene, sulfur, selenium, tellurium, isotactic polypropylene, poly‐4‐methyl‐1‐pentene, poly‐m‐methylstyrene, poly‐o‐methylstyrene, polyoxymethylene, polyisobutylene, polypeptides (α helix, parallel‐chain, or antiparallel‐chain extended form), polyglycine II, polyethylene glycol, and syndiotactic polypropylene were calculated and were used for discussing the structure of these helical polymers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vibrational Spectroscopy and Conformation of Peptides, Polypeptides, and Proteins
Krimm, S., & Bandekar, J. (1986) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60528-8 · Cited by 2,857
Structural studies on polyethers, [‐(CH2)m‐O‐]n. II. Molecular structure of polyethylene oxide
Tadokoro, H., Chatani, Y., Yoshihara, T., Tahara, S., & Murahashi, S. (1964) · Die Makromolekulare Chemie · doi:10.1002/macp.1964.020730109 · Cited by 429
Crystal structure of stereocomplex of poly(L-lactide) and poly(D-lactide)
Okihara, T., Tsuji, M., Kawaguchi, A., Katayama, K.-I., Tsuji, H., Hyon, S.-H., & Ikada, Y. (1991) · Journal of Macromolecular Science, Part B · doi:10.1080/00222349108245788 · Cited by 382
Heat capacities of linear high polymers
Wunderlich, B., & Baur, H. (2006) · Advances in Polymer Science · doi:10.1007/bfb0051029 · Cited by 357
Vasudev, P. G., Chatterjee, S., Shamala, N., & Balaram, P. (2011) · Chemical Reviews · doi:10.1021/cr100100x · Cited by 329
A high-pressure phase of polyethylene and chain-extended growth
Bassett, D. C., Block, S., & Piermarini, G. J. (1974) · Journal of Applied Physics · doi:10.1063/1.1663028 · Cited by 302
Helix Distortion and Crystal Structure of the α-Form of Poly(l-lactide)
Sasaki, S., & Asakura, T. (2003) · Macromolecules · doi:10.1021/ma0348674 · Cited by 296
Mascioni, A., & Veglia, G. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354824 · Cited by 45
Metadata
- Authors
- Miyazawa, T.
- Venue
- Journal of Polymer Science
- Publisher
- Wiley
- Published
- 1961-11
- Volume
- 55
- Issue
- 161
- Pages
- 215-231
- ISSN
- 0022-3832 (ISSN-L)
- 1542-6238
- OpenAlex
- W2032156035
- Cited by
- 213
- References
- 0
- FWCI
- 13.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.