The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
The swelling interface number as a criterion for prediction of diffusional solute release mechanisms in swellable polymers
Abstract
When a glassy polymer containing a uniformly dispersed solute is brought in contact with a penetrant, solute diffusion will be associated with the transport mechanism and penetration velocity of the penetrant in the polymer. Analysis and prediction of mechanisms of diffusional solute release may be obtained through a new dimensionless number, the swelling interface number, Sw, which compares the relative mobilities of the penetrant and the solute in the presence of macromolecular relaxations in the polymer. It is shown that a sufficient and necessary criterion for time‐independent diffusional solute release rates from these swellable systems is that the Sw be smaller than 10−2. The swelling interface number Sw may be related to easily determined structural and thermodynamic parameters of the solute/polymer/penetrant system. Preliminary experimental results of dynamic water swelling of poly(2‐hydroxyethyl methacrylate‐co‐methyl methacrylate) and diffusional release of theophylline from initially glassy copolymers show that decreasing values of Sw are related to increased pseudo‐case‐II transport kinetics of the solute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Present and future applications of biomaterials in controlled drug delivery systems
Langer, R. S., & Peppas, N. A. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90059-4 · Cited by 658
Self-citationPermeability of solutes through hydrated polymer membranes. Part I. Diffusion of sodium chloride
Yasuda, H., Lamaze, C. E., & Ikenberry, L. D. (1968) · Die Makromolekulare Chemie · doi:10.1002/macp.1968.021180102 · Cited by 526
Korsmeyer, R. W., & Peppas, N. A. (1981) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)80265-3 · Cited by 479
Self-citationINVITED REVIEW POLYMERIC DELIVERY SYSTEMS FOR CONTROLLED DRUG RELEASE
LANGER, R. (1980) · Chemical Engineering Communications · doi:10.1080/00986448008912519 · Cited by 288
Controlled Release Delivery Systems
Lonsdale, H. K. (1983) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)81365-4 · Cited by 240
Modelling of drug diffusion through swellable polymeric systems
Peppas, N. A., Gurny, R., Doelker, E., & Buri, P. (1980) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)80471-8 · Cited by 194
Self-citationDiffusion‐controlled stress relaxation in polymers. II. Stress relaxation in swollen polymers
Fujita, H., & Kishimoto, A. (1958) · Journal of Polymer Science · doi:10.1002/pol.1958.1202811806 · Cited by 177
Loshaek, S. (1955) · Journal of Polymer Science · doi:10.1002/pol.1955.120158007 · Cited by 157
Swelling‐controlled, constant rate delivery systems
Hopfenberg, H. B., & Hsu, K. C. (1978) · Polymer Engineering and Science · doi:10.1002/pen.760181511 · Cited by 134
Heat Conduction or Diffusion With Change of Phase
Bankoff, S. G. (1964) · Advances in chemical engineering · doi:10.1016/s0065-2377(08)60007-1 · Cited by 118
Factors affecting water sorption in and solute release from glassy ethylene—vinyl alcohol copolymers
Hopfenberg, H. B., Apicella, A. M., & Saleeby, D. E. (1981) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)82315-7 · Cited by 83
Graham, N. B. (1980) · Biomaterials · doi:10.1016/0142-9612(80)90062-9 · Cited by 14
Cited by
Wound Healing Dressings and Drug Delivery Systems: A Review
Boateng, J. S., Matthews, K. H., Stevens, H. N. E., & Eccleston, G. M. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21210 · Cited by 3,049
Hydrogels: From controlled release to pH-responsive drug delivery
Gupta, P., Vermani, K., & Garg, S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02255-9 · Cited by 1,825
On the importance and mechanisms of burst release in matrix-controlled drug delivery systems
Huang, X., & Brazel, C. S. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00248-6 · Cited by 1,813
Higuchi equation: Derivation, applications, use and misuse
Siepmann, J., & Peppas, N. A. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.03.051 · Cited by 1,088
Self-citationBajpai, S. K., & Sharma, S. (2004) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2004.01.002 · Cited by 752
Metadata
- Authors
- Peppas, N. A., & Franson, N. M.
- Venue
- Journal of Polymer Science: Polymer Physics Edition
- Publisher
- Wiley
- Published
- 1983-06
- Volume
- 21
- Issue
- 6
- Pages
- 983-997
- ISSN
- 0098-1273 (ISSN-L)
- 1542-9385
- OpenAlex
- W2169461768
- Cited by
- 401
- References
- 14
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.