Oxygen diffusion in poly(dimethyl siloxane) using fluorescence quenching. I. Measurement technique and analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The transport properties of oxygen in poly(dimethyl siloxane) have been measured using the method of quenching of fluorescence. This paper discusses the uniqueness of this method and its use in measuring the diffusion coefficient of oxygen in unfilled PDMS. The results show (1) a large value for the diffusion coefficient of oxygen in pure PDMS at 25°C, D = 3.55 × 10−5 cm 2/s, (2) a low value of the acitivation energy, ED = 4.77 kcal/mole, which was not temperature dependent in the ranges evaluated, and (3) a large value of the preexponential term, D0 = 0.115 cm 2/s. The diffusion coefficient was found to be independent of both the oxygen concentration and fluorophor concentration in the pressure and temperature ranges used in these experiments. The import of these experiments lies in their application to a unique biomedical oxygen sensor which is fast, sensitive, and does not consume oxygen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Studies in Newtonian Flow. II. The Dependence of the Viscosity of Liquids on Free-Space
Doolittle, A. K. (1951) · Journal of Applied Physics · doi:10.1063/1.1699894 · Cited by 1,831
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Metabolic origins of spatial organization in the tumor microenvironment
Carmona-Fontaine, C., Deforet, M., Akkari, L., Thompson, C. B., Joyce, J. A., & Xavier, J. B. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1700600114 · Cited by 323
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
An Intrinsically Stretchable Nanowire Photodetector with a Fully Embedded Structure
Yan, C., Wang, J., Wang, X., Kang, W., Cui, M., Foo, C. Y., & Lee, P. S. (2014) · Advanced Materials · doi:10.1002/adma.201304226 · Cited by 191
Metadata
- Authors
- Cox, M. E., & Dunn, B.
- Venue
- Journal of Polymer Science Part A: Polymer Chemistry
- Publisher
- Wiley
- Published
- 1986-04
- Volume
- 24
- Issue
- 4
- Pages
- 621-636
- ISSN
- 0887-624X (ISSN-L)
- 1099-0518
- OpenAlex
- W2123456749
- Cited by
- 88
- References
- 1
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen diffusion in poly(dimethyl siloxane) using fluorescence quenching. I. Measurement technique and analysis. https://app.cochat.ai/papers/10.1002/pola.1986.080240405
- The paper
- Cox, M. E., & Dunn, B. (1986). Oxygen diffusion in poly(dimethyl siloxane) using fluorescence quenching. I. Measurement technique and analysis. Journal of Polymer Science Part A: Polymer Chemistry. https://doi.org/10.1002/pola.1986.080240405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.