Synthesis of amphiphilic and thermosensitive graft copolymers with fluorescence P(St‐co‐(p‐CMS))‐g‐PNIPAAM by combination of NMP and RAFT methods
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A three‐step process, combining nitroxide‐mediated polymerization (NMP) and reversible addition‐fragmentation chain transfer (RAFT) polymerization techniques, for synthesizing well‐defined amphiphilic and thermosensitive graft copolymers with fluorescence poly(styrene‐co‐(p‐chloromethylstyrene))‐g‐poly(N‐isopropylacrylamide) (P(St‐co‐(p‐CMS))‐g‐PNIPAAM), was conducted. Firstly, the NMP of styrene (St) and p‐chloromethylstyrene (p‐CMS) were carried out using benzoyl peroxide (BPO) as the initiator to obtain the random copolymers of P(St‐co‐(p‐CMS)). Secondly, the random copolymers were converted into macro‐RAFT agents with fluorescent carbazole as Z‐group through a simple method. Then the macro‐RAFT agents were used in the RAFT polymerization of N‐isopropylacrylamide (NIPAAM) to prepare fluorescent amphiphilic graft copolymers P(St‐co‐(p‐CMS))‐g‐PNIPAAM with controlled molecular weights and well‐defined structures. The copolymers obtained were characterized by gel permeation chromatography (GPC), 1 H nuclear magnetic resonance (NMR) spectroscopy, and FT‐IR spectroscopy. The size of self‐assembly micelles of the resulting graft copolymers in deionized water was studied by high performance particle sizer (HPPS), the results showed that the Z‐average size of the micelles increased with the increase of molecular weights of PNIPAAM in side chains. The aqueous solution of the micelles prepared from P(St‐co‐(p‐CMS))‐g‐PNIPAAM using a dialysis method showed a lower critical solution temperature (LCST) at ∼ 27.5 °C, which was below the value of NIPAAM homopolymer (32 °C). © 2007 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 45: 5318–5328, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross-linked polymersome membranes: Vesicles with broadly adjustable properties
Discher, B. M., Bermudez, H., Hammer, D. A., Discher, D. E., Won, Y.-Y., & Bates, F. S. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp011958z · Cited by 262
You, Y., Hong, C., Wang, W., Lu, W., & Pan, C. (2004) · Macromolecules · doi:10.1021/ma048444t · Cited by 151
Cited by
Nitroxide-mediated polymerization
Nicolas, J., Guillaneuf, Y., Lefay, C., Bertin, D., Gigmes, D., & Charleux, B. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.06.002 · Cited by 1,380
Gregory, A., & Stenzel, M. H. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.004 · Cited by 470
Thermo-responsive shell cross-linked PMMA-b-P(NIPAAm-co-NAS) micelles for drug delivery
Chang, C., Wei, H., Wu, D.-Q., Yang, B., Chen, N., Cheng, S.-X., Zhang, X.-Z., & Zhuo, R.-X. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.08.038 · Cited by 46
Metadata
- Authors
- Wang, S., Cheng, Z., Zhu, J., Zhang, Z., & Zhu, X.
- Venue
- Journal of Polymer Science Part A: Polymer Chemistry
- Publisher
- Wiley
- Published
- 2007-10-04
- Volume
- 45
- Issue
- 22
- Pages
- 5318-5328
- ISSN
- 0887-624X (ISSN-L)
- 1099-0518
- OpenAlex
- W2172224326
- Cited by
- 39
- References
- 2
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.