CoChat

Spirometry in children aged 3 to 5 years: Reliability of forced expiratory maneuvers*

Open access
Crenesse, D., Berlioz, M., Bourrier, T., Albertini, M. · 2001 · Pediatric Pulmonology
Cited by 160

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The aim of this study was to evaluate the feasibility and reproducibility of forced expiratory maneuvers during standard spirometric evaluation in preschool children. Among 570 young children attending our laboratory, we retrospectively selected 355 patients (14% 3–4‐year‐olds, 48% 4–5‐year‐olds, and 38% 5–6‐year‐olds) who carried out spirometric tests for the first time. The indications for such tests were history of asthma (70%), followed by chronic cough (20%) and other miscellaneous conditions (10%). Eighty‐eight, 175, and 92 children performed one, two, and three acceptable tests respectively. Forced expired volume in 1 sec (FEV 1) and forced vital capacity (FVC) did not differ significantly between attempts in children performing either two or three attempts. Forced expiratory time (FET), i.e., the total time required for the forced expiratory maneuver, was 1.7 ± 0.1 sec (mean ± SEM), and was no greater than 1 sec in 21.3% of all tested children. Consequently, FEV 1 does not appear to be well‐suited to this age group. Forced expiratory volume in 0.50 and 0.75 sec (FEV 0.5, FEV 0.75) were thus measured in the group of children performing three attempts (n = 92), and there was no statistical difference between attempts. In 267 children performing two or three tests, the ATS criteria of reproducing FEV 1 and FVC within ≤ 0.1 L seemed to be preferable in this young population. Indeed, more than 70% of the tested children presented their two best efforts (FVC and FEV 1) not varying by more than 0.1 L. Individual coefficients of variation (CV = SD/mean×100%) over three tests for FEV 1 and FVC were 6.71 ± 0.53% and 6.35 ± 0.41% (mean ± SEM), respectively. These results show that forced expiratory tests are not always feasible in young children, but that 55% (196/355) of our selected population performed reliable maneuvers (at least two FVC and FEV 1 reproducible within 0.1 L), provided that they were supervised by a carefully trained pediatric medical staff. Pediatr Pulmonol. 2001; 32:56–61. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ppul.1089

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Crenesse, D., Berlioz, M., Bourrier, T., & Albertini, M.
Venue
Pediatric Pulmonology
Publisher
Wiley
Published
2001-06-14
Volume
32
Issue
1
Pages
56-61
ISSN
  • 1099-0496 (ISSN-L)
  • 8755-6863
OpenAlex
W2015146607
Cited by
160
References
13
FWCI
5.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.