The DOI matches its Crossref record.
High‐flow nasal cannula: Impact on oxygenation and ventilation in an acute lung injury model
Open accessAbstract
Introduction: High‐flow nasal cannula therapy (HFNC) has been shown to be more effective than continuous positive airway pressure (CPAP) in reducing intubations and ventilator days. HFNC likely provides mechanisms to support respiratory efficiency beyond application of distending pressure. We reason that HFNC washout of nasopharyngeal dead space impacts CO 2 removal along with oxygenation. The aim of this study was to demonstrate the flow dependence of CO 2 reduction and improved oxygenation during HFNC and the dependence on leak around the nasal prongs. Materials and Methods: Neonatal piglets (n = 13; 2–6 kg) were injured with IV oleic acid and supported with HFNC at 2 through 8 L/min. High and low leak around the nasal prongs was accomplished by using single and double prong cannulae, respectively. Measurement of hemodynamic, respiratory and blood gas parameters were made at each setting following 10 min for physiologic equilibration. Tracheal pressures were recorded by transmural catheters. Results: With HFNC, CO 2 trended downward in a flow‐dependent manner independent of leak. Oxygenation and tracheal pressures increased in a flow‐dependent manner with the greatest effect during double prong. At 8 L/min, tracheal pressures did not exceed 6 ± 1 cmH 2 O. Conclusions: HFNC improves gas exchange in a flow‐dependent manner; double prong had greater impact on O 2; single prong had greater impact on CO 2 elimination. Pediatr Pulmonol. 2011; 46:67–74. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heated Humidified High-Flow Nasal Oxygen in Adults
Spoletini, G., Alotaibi, M., Blasi, F., & Hill, N. S. (2015) · Chest · doi:10.1378/chest.14-2871 · Cited by 406
Lee, J. H., Rehder, K. J., Williford, L., Cheifetz, I. M., & Turner, D. A. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2743-5 · Cited by 391
High flow nasal cannula for respiratory support in preterm infants
Wilkinson, D., Andersen, C., O'Donnell, C. P., De Paoli, A. G., & Manley, B. J. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006405.pub3 · Cited by 368
High-flow nasal cannula oxygen therapy in adults
Nishimura, M. (2015) · Journal of Intensive Care · doi:10.1186/s40560-015-0084-5 · Cited by 332
Nasal high flow clears anatomical dead space in upper airway models
Möller, W., Celik, G., Feng, S., Bartenstein, P., Meyer, G., Eickelberg, O., Schmid, O., & Tatkov, S. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00934.2014 · Cited by 320
Metadata
- Authors
- Frizzola, M., Miller, T. L., Rodriguez, M. E., Zhu, Y., Rojas, J., Hesek, A., Stump, A., Shaffer, T. H., & Dysart, K.
- Venue
- Pediatric Pulmonology
- Publisher
- Wiley
- Published
- 2010-11-23
- Volume
- 46
- Issue
- 1
- Pages
- 67-74
- ISSN
- 1099-0496 (ISSN-L)
- 8755-6863
- OpenAlex
- W2054504961
- Cited by
- 226
- References
- 0
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐flow nasal cannula: Impact on oxygenation and ventilation in an acute lung injury model. https://app.cochat.ai/papers/10.1002/ppul.21326
- The paper
- Frizzola, M., Miller, T. L., Rodriguez, M. E., Zhu, Y., Rojas, J., Hesek, A., Stump, A., Shaffer, T. H., & Dysart, K. (2011). High‐flow nasal cannula: Impact on oxygenation and ventilation in an acute lung injury model. Pediatric Pulmonology. https://doi.org/10.1002/ppul.21326
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.