The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reliability of detecting ‘onset of pain’ and ‘submaximal pain’ during neural provocation testing of the upper quadrant
Abstract
Background and Purpose: Conflicting results have been reported with regard to the reliability of neural tissue provocation tests and it is unclear whether repeated testing affects the test results. In the present study, the stability and reliability of the occurrence of ‘onset of pain’ and ‘submaximal pain’ throughout the range of motion during neurodynamic testing was analysed, in both a laboratory and a clinical setting. Method: A repeated‐measures study design within and between sessions was used. In the laboratory and clinical settings, the base neurodynamic test for the median nerve was performed during a single session on a total of 27 patients with neurogenic cervico‐brachial pain. In addition, the base test and three common variations were performed on two occasions by two examiners on 10 asymptomatic subjects in laboratory conditions only. Patients indicated the moment of ‘submaximal pain’ occurrence, whereas asymptomatic subjects indicated ‘onset of pain’ and ‘submaximal pain’. Corresponding angles at the elbow were recorded by use of an electrogoniometer. Results: In the asymptomatic group, the intra‐ and inter‐tester reliability within the same session was excellent (intraclass correlation coefficient (ICC 2,1 ≥ 0.95; standard error of measurement (SEM) ≤4.9°). Reliability after a 48‐hour interval was moderate (ICC 2,1 ≥ 0.69; SEM ≤ 9.9°). The reliability coefficients for the symptomatic group within the same session were comparable with the excellent results of the asymptomatic group, for both the laboratory (ICC 2,1 = 0.98; SEM = 2.8°) and clinical settings (ICC 2,1 ≥ 0.98; SEM ≤ 3.4°). Consequently, from a statistical perspective, improvements in range of motion as small as approximately 7.5° may be interpreted meaningfully. No significant trend due to repeated testing could be observed when three consecutive repetitions were analysed. Conclusions: Pain provocation during neurodynamic testing is a stable phenomenon and the range of elbow extension corresponding with the moment of ‘pain onset’ and ‘submaximal pain’ may be measured reliably, both in laboratory and clinical conditions. Copyright © 2002 Whurr Publishers Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Nijs, J., Van Houdenhove, B., & Oostendorp, R. A. B. (2010) · Manual Therapy · doi:10.1016/j.math.2009.12.001 · Cited by 505
Between-Session Reliability of Four Hop Tests and the Agility T-Test
Munro, A. G., & Herrington, L. C. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181d83335 · Cited by 328
Rubinstein, S. M., Pool, J. J. M., van Tulder, M. W., Riphagen, I. I., & de Vet, H. C. W. (2007) · European Spine Journal · doi:10.1007/s00586-006-0225-6 · Cited by 272
Munro, A., Herrington, L., & Carolan, M. (2012) · Journal of Sport Rehabilitation · doi:10.1123/jsr.21.1.7 · Cited by 265
The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.
Nee, R. J., Jull, G. A., Vicenzino, B., & Coppieters, M. W. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.3988 · Cited by 171
Self-citation
Metadata
- Authors
- Coppieters, M., Stappaerts, K., Janssens, K., & Jull, G.
- Venue
- Physiotherapy Research International
- Publisher
- Wiley
- Published
- 2002-08
- Volume
- 7
- Issue
- 3
- Pages
- 146-156
- ISSN
- 1358-2267 (ISSN-L)
- 1471-2865
- OpenAlex
- W2044742587
- Cited by
- 175
- References
- 1
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.