The six‐minute walk test in outpatients with obesity: reproducibility and known group validity
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background and Purpose. To assess the reproducibility and validity of the six‐minute walk test (6MWT) in men and women with obesity in order to facilitate evaluation of treatment outcome. Method. A test—retest design was used to test reproducibility and a comparative design to test known group validity. Forty‐three obese outpatients (16 male), mean age 47 (21–62) years, mean body mass index (BMI) 40 (3–62)kg‐m–2 performed the 6MWT twice within one week. Intraclass correlation (ICC1.1) and measurement error (S w) were calculated from the mean square values derived from a one‐way repeated‐measures ANOVA (fixed effect model). The reproducibility was also analysed by means of coefficient of variation (CV) and the Bland Altman method including 95% limits of agreement. The variance of the distance walked was analysed by means of regressions. The known group validity of the 6MWT (distance walked and the work of walking) in obese participants was shown by comparisons with 41 lean participants (18 male), mean age 47 (24–65) years, mean BMI 22.7kg‐m–2 (19–25). Results. The obese group walked 534 m (confidence interval [CI] 508–560 the first and 552 m (CI 523–580) the second walk (p < 0.001). S w was 25 m, CV 4.7%, ICC1.1 was 0.96. The limits of agreement were –46 m+80 m. The validity tests showed that they walked 162 m shorter (p < 0.001) and performed much heavier work (p < 0.001) than the lean group. In the obese group, BMI alone explained 38% of the variance of the distance walked. Conclusions. The 6MWT showed good reproducibility and known group validity and can be recommended for evaluating walking ability in subjects with obesity. For individual evaluation, however, an improved walking distance of at least 80 m was required to make the difference clinically significant. Despite shorter walking distance the obese participants performed heavier work than the lean. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
Redelmeier, D. A., Bayoumi, A. M., Goldstein, R. S., & Guyatt, G. H. (1997) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.155.4.9105067 · Cited by 1,029
Cited by
Bartels, S. J., Pratt, S. I., Aschbrenner, K. A., Barre, L. K., Naslund, J. A., Wolfe, R., Xie, H., McHugo, G. J., Jimenez, D. E., Jue, K., et al. (2015) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2014.14030357 · Cited by 188
“In obese adults, the 6-MWT is a reliable and valid measure of fitness with favorable test-retest and discriminant validity (25, 26), and has been used in adults with a variety of chronic health conditions (27-36).”
BackgroundBartels, S. J., Pratt, S. I., Aschbrenner, K. A., Barre, L. K., Jue, K., Wolfe, R. S., Xie, H., McHugo, G., Santos, M., Williams, G. E., et al. (2013) · Psychiatric Services · doi:10.1176/appi.ps.003622012 · Cited by 188
“For obese adults, the 6MWT is a reliable and valid measure of cardiovascular fitness with favorable test-retest and discriminant validity (16,17) and has been used with adults with a variety of chronic health conditions (18–27).”
Naslund, J. A., Aschbrenner, K. A., Scherer, E. A., McHugo, G. J., Marsch, L. A., & Bartels, S. J. (2016) · Psychiatry Research · doi:10.1016/j.psychres.2016.06.056 · Cited by 86
“The 6-MWT is considered a reliable and valid measure of fitness (Beriault et al., 2009; Larsson and Reynisdottir, 2008) and has demonstrated reproducibility in people with serious mental illness (Vancampfort et al., 2011).”
BackgroundNaslund, J. A., Aschbrenner, K. A., Marsch, L. A., McHugo, G. J., & Bartels, S. J. (2018) · Psychiatric Quarterly · doi:10.1007/s11126-017-9512-0 · Cited by 64
Aschbrenner, K. A., Naslund, J. A., Shevenell, M., Kinney, E., & Bartels, S. J. (2016) · Journal of Nervous & Mental Disease · doi:10.1097/nmd.0000000000000530 · Cited by 60
“Cardiorespiratory fitness was assessed with the 6-minute walk test (6-MWT), which measures the distance (feet) an individual can walk in 6 minutes (Larsson and Reynisdottir, 2008).”
Metadata
- Authors
- Larsson, U. E., & Reynisdottir, S.
- Venue
- Physiotherapy Research International
- Publisher
- Wiley
- Published
- 2008-04-30
- Volume
- 13
- Issue
- 2
- Pages
- 84-93
- ISSN
- 1358-2267 (ISSN-L)
- 1471-2865
- OpenAlex
- W2020454688
- Cited by
- 149
- References
- 4
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The six‐minute walk test in outpatients with obesity: reproducibility and known group validity. https://app.cochat.ai/papers/10.1002/pri.398
- The paper
- Larsson, U. E., & Reynisdottir, S. (2008). The six‐minute walk test in outpatients with obesity: reproducibility and known group validity. Physiotherapy Research International. https://doi.org/10.1002/pri.398
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.