The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Critical assessment of the automated AutoDock as a new docking tool for virtual screening
Abstract
A major problem in virtual screening concerns the accuracy of the binding free energy between a target protein and a putative ligand. Here we report an example supporting the outperformance of the AutoDock scoring function in virtual screening in comparison to the other popular docking programs. The original AutoDock program is in itself inefficient to be used in virtual screening because the grids of interaction energy have to be calculated for each putative ligand in chemical database. However, the automation of the AutoDock program with the potential grids defined in common for all putative ligands leads to more than twofold increase in the speed of virtual database screening. The utility of the automated AutoDock in virtual screening is further demonstrated by identifying the actual inhibitors of various target enzymes in chemical databases with accuracy higher than the other docking tools including DOCK and FlexX. These results exemplify the usefulness of the automated AutoDock as a new promising tool in structure‐based virtual screening. Proteins 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipinski, C. A., Lombardo, F., Dominy, B. W., & Feeney, P. J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00129-0 · Cited by 18,139
Friesner, R. A., Banks, J. L., Murphy, R. B., Halgren, T. A., Klicic, J. J., Mainz, D. T., Repasky, M. P., Knoll, E. H., Shelley, M., Perry, J. K., et al. (2004) · Journal of Medicinal Chemistry · doi:10.1021/jm0306430 · Cited by 10,057
Charifson, P. S., Corkery, J. J., Murcko, M. A., & Walters, W. P. (1999) · Journal of Medicinal Chemistry · doi:10.1021/jm990352k · Cited by 698
Comparative evaluation of eight docking tools for docking and virtual screening accuracy
Kellenberger, E., Rodrigo, J., Muller, P., & Rognan, D. (2004) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.20149 · Cited by 577
Cited by
An improved relaxed complex scheme for receptor flexibility in computer-aided drug design
Amaro, R. E., Baron, R., & McCammon, J. A. (2008) · Journal of Computer-Aided Molecular Design · doi:10.1007/s10822-007-9159-2 · Cited by 321
The effect of ligand-based tautomer and protomer prediction on structure-based virtual screening.
Kalliokoski, T., Salo, H. S., Lahtela-Kakkonen, M., & Poso, A. (2009) · Journal of Chemical Information and Modeling · doi:10.1021/ci900364w · Cited by 66
DockOpt: A Tool for Automatic Optimization of Docking Models
(2024) · doi:10.1021/acs.jcim.3c01406 · Cited by 7
Metadata
- Authors
- Park, H., Lee, J., & Lee, S.
- Venue
- Proteins: Structure, Function, and Bioinformatics
- Publisher
- Wiley
- Published
- 2006-09-20
- Volume
- 65
- Issue
- 3
- Pages
- 549-554
- ISSN
- 0887-3585 (ISSN-L)
- 1097-0134
- OpenAlex
- W2089188080
- Cited by
- 186
- References
- 4
- FWCI
- 9.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.