Asymmetric amyloid fibril elongation: a new perspective on a symmetric world
Abstract
Amyloids are insoluble, fibrous proteins formed through the aggregation of misfolded proteins. They accumulate in the tissue of individuals with degenerative diseases, such as Parkinson's and Alzheimer's. The purpose of this study was to determine whether fibril growth from an initial model fibril seed is unidirectional or bidirectional. The prevailing theory on amyloid formation is that a symmetric fibril elongates equally from both ends. This study provides evidence to the contrary; the process occurs predominately unidirectionally, demonstrating that amyloid fibrils may be asymmetric and propagate mostly in one direction. Alexa Fluor 568 labeled insulin fibrils were seeded into a native insulin solution and allowed to elongate at 65°C while the kinetics of fibril growth was monitored. The resulting elongated fibrils were labeled with thioflavin-T, and the fluorescent images of the fibrils show that a majority of the elongated fibrils propagated along only one end of the seed, with the remaining labeled fibrils having bidirectional elongation or no elongation. Using a crystallographic model, we offer a structural explanation for asymmetric growth of the insulin fibrils. Thus, instead of the current view that fibrils grow symmetrically from both ends of the fibril, this is the first evidence that insulin amyloid fibrils formed in solution are asymmetric and appear to grow from only one end.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Asymmetric growth of amyloid fibrils has been previously described.
“This would be in line with the previously described asymmetric growth of amyloid fibrils (73).”
From MAP2 caps tau fibrils and inhibits aggregation (2023) · cites this paper as [73]
The two ends of the fibril are asymmetric.
“Another important aspect of capping is that the two ends of the fibril are asymmetric.”
From MAP2 caps tau fibrils and inhibits aggregation (2023) · cites this paper as [73]
The citation lists haven’t been fetched yet
References 28 · Cited by 30
- Authors
- Heldt, C. L., Zhang, S., & Belfort, G.
- Affiliations
- Michigan Technological University (US)
- Rensselaer Polytechnic Institute (US)
- Corresponding author
- Belfort, Georges
- Venue
- Proteins: Structure, Function, and Bioinformatics
- Publisher
- Wiley
- Published
- 2010-10-12
- Volume
- 79
- Issue
- 1
- Pages
- 92-98
- ISSN
- 0887-3585 (ISSN-L)
- 1097-0134
- OpenAlex
- W2037435891
- Cited by
- 30
- References
- 28
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 4 · 2022: 1 · 2021: 2 · 2020: 2 · 2017: 1 · 2016: 4 · 2015: 3 · 2014: 2 · 2013: 3 · 2012: 2
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proteins Structure Function and Bioinformatics (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons - Michigan Tech (Michigan Technological University) (submittedVersion)
- Funders
- Novo Nordisk
- Topics
- Health Sciences › Medicine › Physiology › Alzheimer's disease research and treatments
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Prion Diseases and Protein Misfolding
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Keywords
- insulin amyloid fibrils, protein aggregation, fibril growth kinetics, protein misfolding, Parkinson's disease, Alzheimer's disease
- MeSH terms
- Amyloid, Insulin, Polymerization, Protein Unfolding
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review