The DOI matches its Crossref record.
Product ion scanning using a Q‐q‐Q linear ion trap (Q TRAP TM ) mass spectrometer
Abstract
The use of a Q‐q‐Q linear ion trap instrument to obtain product ion spectra is described. The instrument is based on the ion path of a triple quadrupole mass spectrometer with Q3 operable as either a conventional RF/DC quadrupole mass filter or a linear ion trap mass spectrometer with axial ion ejection. This unique ion optical arrangement allows de‐coupling of precursor ion isolation and fragmentation from the ion trap itself. The result is a high sensitivity tandem mass spectrometer with triple quadrupole fragmentation patterns and no inherent low mass cut‐off. The use of the entrance RF‐only section of the instrument as accumulation ion trap while the linear ion trap mass spectrometer is scanning enhances duty cycles and results in increased sensitivities by as much as a factor of 20. The instrument is also capable of all of the triple quadrupole scans including multiple‐reaction monitoring (MRM) as well as precursor and constant neutral loss scanning. The high product ion scanning sensitivity allows the recording of useful product ion spectra near the MRM limit of quantitation. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Mass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
Analytical strategies for identifying drug metabolites
Prakash, C., Shaffer, C. L., & Nedderman, A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20128 · Cited by 302
Selected reaction monitoring applied to proteomics
Gallien, S., Duriez, E., & Domon, B. (2011) · Journal of Mass Spectrometry · doi:10.1002/jms.1895 · Cited by 286
Metadata
- Authors
- Hager, J. W., & Yves Le Blanc, J. C.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-04-02
- Volume
- 17
- Issue
- 10
- Pages
- 1056-1064
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2118310130
- Cited by
- 161
- References
- 0
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Product ion scanning using a Q‐q‐Q linear ion trap (Q TRAP TM ) mass spectrometer. https://app.cochat.ai/papers/10.1002/rcm.1020
- The paper
- Hager, J. W., & Yves Le Blanc, J. C. (2003). Product ion scanning using a Q‐q‐Q linear ion trap (Q TRAP TM ) mass spectrometer. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.