Two new organic reference materials for δ 13 C and δ 15 N measurements and a new value for the δ 13 C of NBS 22 oil
Abstract
Analytical grade L‐glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L‐glutamic acid reference materials with substantially different 13 C and 15 N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L‐glutamic acid and has a δ 13 C value of −26.24‰ relative to VPDB and a δ 15 N value of −4.52‰ relative to N 2 in air. USGS41 was prepared by dissolving analytical grade L‐glutamic acid with L‐glutamic acid enriched in 13 C and 15 N. USGS41 has a δ 13 C value of +37.76‰ and a δ 15 N value of +47.57‰. The δ 13 C and δ 15 N values of both materials were measured against the international reference materials NBS 19 calcium carbonate ( δ 13 C = +1.95‰), L‐SVEC lithium carbonate ( δ 13 C = −46.48‰), IAEA‐N‐1 ammonium sulfate ( δ 15 N = 0.43‰), and USGS32 potassium nitrate ( δ 15 N = 180‰) by on‐line combustion continuous‐flow and off‐line dual‐inlet isotope‐ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ 13 C is better than 0.13‰, and that of δ 15 N is better than 0.13‰ in 100‐μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass‐dependent fractionations, and isotope‐ratio‐scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ 13 C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off‐line blank corrections probably have not been quantified satisfactorily. Published in 2003 by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Isotopic Chemistry of Carbonates and a Paleotemperature Scale
McCrea, J. M. (1950) · The Journal of Chemical Physics · doi:10.1063/1.1747785 · Cited by 3,742
Referencing strategies and techniques in stable isotope ratio analysis
Werner, R. A., & Brand, W. A. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.258 · Cited by 1,033
Self-citation
Cited by
Isotopic evidence for biological nitrogen fixation by molybdenum-nitrogenase from 3.2 Gyr
Stüeken, E. E., Buick, R., Guy, B. M., & Koehler, M. C. (2015) · Nature · doi:10.1038/nature14180 · Cited by 308
Best practices for calibrating and reporting stable isotope measurements in archaeology
Szpak, P., Metcalfe, J. Z., & Macdonald, R. A. (2017) · Journal of Archaeological Science: Reports · doi:10.1016/j.jasrep.2017.05.007 · Cited by 272
WALKER, B., ARIZA, L. S., KAINES, S., BADGER, M. R., & COUSINS, A. B. (2013) · Plant, Cell & Environment · doi:10.1111/pce.12166 · Cited by 163
Crowley, S. F., Spero, H. J., Winter, D. A., Sloane, H. J., & Croudace, I. W. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3518 · Cited by 9
Metadata
- Authors
- Qi, H., Coplen, T. B., Geilmann, H., Brand, W. A., & Böhlke, J. K.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-10-23
- Volume
- 17
- Issue
- 22
- Pages
- 2483-2487
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2122653354
- Cited by
- 247
- References
- 2
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.