The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Matrix‐assisted laser‐desorption mass spectrometry using 355 nm radiation
Abstract
Matrix‐assisted laser desorption of proteins with the 355 nm frequency‐tripled output of a neodymium:yttrium‐aluminium‐garnet laser has been demonstrated. In order to produce desorption at this wavelength, the cinnamic acid derivatives ferulic, caffeic and sinapinic acids have been employed as matrices. Excellent sensitivity (routinely one pmol of protein) and good mass resolution ( m /Δ m 400, Full width at half maximum) have been obtained by this new method. Ultraviolet photo‐spectrometry of the cinnamic acid derivative matrices suggests strongly that they can be used as protein laser‐desorption matrices at any wavelength between 260 nm and 360 nm, allowing the development of laser‐desorption mass spectrometers based on nitrogen or excimer lasers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Matrix‐assisted laser desorption ionization mass spectrometry
Karas, M., Bahr, U., & Gießmann, U. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100503 · Cited by 377
Rapid, sensitive analysis of protein mixtures by mass spectrometry.
Beavis, R. C., & Chait, B. T. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.17.6873 · Cited by 301
Self-citationBeavis, R. C., & Chait, B. T. (1991) · Chemical Physics Letters · doi:10.1016/0009-2614(91)90384-l · Cited by 269
Self-citation
Metadata
- Authors
- Beavis, R. C., Chait, B. T., & Standing, K. G.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1989-12
- Volume
- 3
- Issue
- 12
- Pages
- 436-439
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1983939557
- Cited by
- 190
- References
- 1
- FWCI
- 13.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Matrix‐assisted laser‐desorption mass spectrometry using 355 nm radiation. https://app.cochat.ai/papers/10.1002/rcm.1290031208
- The paper
- Beavis, R. C., Chait, B. T., & Standing, K. G. (1989). Matrix‐assisted laser‐desorption mass spectrometry using 355 nm radiation. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1290031208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.